5.4.2

The "Tag Data" tab

The "Tag Data" tab is displayed only in the advanced view.
Using the "Tag Data" tab, you can verify the transponder data and the basic function of a
reading point quickly and simply. In this tab, you can read out any data from the transponder
or write to the transponder. When writing to the transponder, you can address all memory
areas of the transponder. With a single command, a maximum of 64 bytes can be read or
written.
You can also change the EPC-ID of the transponder.
Figure 5-7
Selecting transponders
In the drop-down list of the "Tag to access" area, you can choose the antenna via which the
reader will establish the connection to the transponder.
The "Tag ID" list contains all the transponders in the antenna field. You can update the list
with the "Read Tag ID" button. From this list, select the transponder for which you want to
use write or read operations.