5. Define display resolution of the monitor attached directly to
Transmitter. If local display not required at Transmitter, skip this
step.
If display do not show desirably, or specific resolution required,
define setting as below-
Select desired resolution from one of the option from table
below. Adjust "EDID DIP" switch, refer to table below. "0"
represents switch down. "1" represents switch up.
After DIP Switch set, press "SET" button to register setting.
NOTE: Transmitter factory default setting is 1080p 60Hz video.
NOTE: Receiver sets Bypass mode, Transmitter sets Read
LOCAL OUTPUT EDID- Transmitter automatically reads EDID
from attached monitor and feeds the same setting to all monitors
attached to Receiver. When no local monitor directly connected
to Transmitter, EDID will be undetectable and may result
display error.
6. Power on connected devices on Transmitter side- local monitor
(if any) and video source.
7. Power on all monitors attached to Receiver.
8. Use "Focus" and "Gain" knobs to fine tune monitor's picture
quality.