Download  Print this page

HP Z4 G4 Maintenance And Service Manual Page 75

Hide thumbs

Advertisement

Control panel message
00C-PMM Deallocation Error during MEBx
Cleanup
00D-Setup Error during MEBx Execution
00E-Inventory Error during MEBx Execution
00F-Interface Error during MEBx Execution
100-Front Audio Not Connected
2E1-MemorySize Error
2E2-Memory Error
Description
Memory error during POST execution of
the Management Engine (ME) BIOS Extensions
option ROM.
MEBx selection or exit resulted in a setup
failure.
BIOS information passed to the MEBx resulted
in a failure.
MEBx operation experienced a hardware error
during communication with the ME.
Front audio cable has been detached or
unseated from system board.
Memory amount has changed since the last
boot (memory added or removed).
Memory module configuration failed during
boot up.
Recommended action
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
Unplug the power cord, re-seat
the memory modules, and reboot
the computer.
3.
If the memory configuration was recently
changed, unplug the power cord, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
Unplug the power cord, re-seat
the memory modules, and reboot
the computer.
3.
If the memory configuration was recently
changed, unplug the power cord, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace
the system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace
the system board.
Reconnect or replace front audio cable.
The system memory size is different from
the last startup. The most common reason is
the removal of memory from the system board.
Press the
F1
key to save the memory changes.
If this message persists, verify that
the memory modules are installed correctly.
1.
Ensure memory modules are correctly
installed.
2.
Verify proper memory module type.
3.
Remove and replace the identified faulty
memory module(s).
4.
If the error persists after replacing
memory modules, replace the system
board.
POST numeric codes and text messages
67

Advertisement

Table of Contents

   Related Manuals for HP Z4 G4

Comments to this Manuals

Symbols: 0
Latest comments: