1.5 Specifications

Module Name
Catalogue
Protocol Supported
Connectors
LAN
Number of IP addresses One
Number of Ethernet
Ports
Embedded Ethernet
Switch
Serial Port
Modules per RX3i CPU
Number of 104 Clients
supported per module
Number of 104 Sectors
supported per module
Number of 104 Clients
supported per RX3i CPU
Number of 104 points
per module
Network Topology
supported
Hot Swappable
Time Synchronization
Power Requirements
For system standards, general operating specifications, and installation requirements, refer to
PACSystems RX3i System Manual, GFK-2314.
1
Two Protection objects (M_EP_TB_1 and M_EP_TC_1) are only accessible through Point Push and not as Controller points.
This constitutes 2048 points (1024 each) and is included in the total number of Points per Module.
GFK-2949C
PACSystems RX3i Ethernet 104 Server Module
IC695EIS001-AA
IEC60870-5-104 Server
- Station Manager (RS-232) Port: 9-pin female D-connector
- Two 10BaseT / 100BaseTX Ports: 8-pin female shielded RJ-45
IEEE 802.2 Logical Link Control Class I
IEEE 802.3 CSMA/CD Medium Access Control 10/100 Mbps
Two. Both are 10BaseT / 100BaseTX with auto-sensing. Connectors are RJ-45.
Yes – Allows daisy-chaining of Ethernet nodes.
Station Manager Port:
4
8
Refer to the sections Multiple Client Connection Configuration and
COMMREQ –Shift RBE on Client Connection Associated With a Specified Port Number
One
4 per RX3i CPU
6144
1
Star, Line, Daisy Chain
Yes
SNTP Client
3.3Vdc: 0.840 A maximum
5 Vdc: 0.614 A maximum
RS-232 DCE, 1200 – 115,200 bps.
July 2017
Chapter 1. Introduction
5