GSMX4G / GSMXCN4G Installation and Setup Guide
SPACE
[SPACE]: For scrolling option list
0
[0]: For entering the number 0
#/ENTER
[#/ENTER]: Starts programming
mode; Press to accept entries
* Active only when the "Exit Programming Mode" prompt is displayed.

Programming Conventions

Programming is accomplished by answering a series of prompts.
Most prompts require only a [Y]es or [N]o response, while others
require a numerical response (ID numbers, etc.).
The current value is displayed on the second line in parentheses ( ).
A "?" indicates an invalid entry.
Use the [] key to scroll through options.
Use the [ENTER] key to accept the current entry and proceed to the
next prompt. If the entered value is invalid, pressing [ENTER] re-
displays the prompt; the next prompt is not displayed until a valid
answer is entered.
Use the up/down arrow keys to scroll through the programming
prompts without changing any values.
Press the [ESC] key to go to the end of the list of prompts.

Using the Control Panel

Some control panels support programming of the communicator through the
control panel programming mode. If using this method of programming, only
the ECP Mode programming options are available. Other "mode" prompts
will not be displayed, and the mode cannot be changed. For a description of
key functions on the control panel keypad, and how they map to the 7720P
programming tool, refer to the control panel's Programming Guide.

Programming for ECP Mode

The communicator supports ECP messaging to communicate with the control
panel. Likewise the control panel sends Contact ID format alarms to the
communicator via the ECP bus. Not all control panels support the
communicator interface on ECP, so be sure to check the control panel's
Installation and Setup Guide to see if it supports this feature.
ULC
Only ECP Mode has been approved for ULC installations.
Press the [ENTER] key to begin programming.
No SHIFT function
No SHIFT function
No SHIFT function