Avonic AV-CON300 User Manual

Ptz camera controller
Hide thumbs Also See for AV-CON300:

Advertisement

Quick Links

Avonic AV-CON300
PTZ Camera Controller
User Manual
Version 1.1
Update notes:
www.avonic.eu
Join Avonic
linkedin.com/company/avonic
twitter.com/avonic1
facebook.com/avonic
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AV-CON300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Avonic AV-CON300

  • Page 1 Avonic AV-CON300 PTZ Camera Controller User Manual Version 1.1 Update notes: Join Avonic linkedin.com/company/avonic twitter.com/avonic1 facebook.com/avonic www.avonic.eu...
  • Page 2: Table Of Contents

    Display ..............................11 Menu ..............................11 Operation ............................13 1. Boot ............................13 2. Select the camera number ......................13 3. PTZ operation ..........................13 4. Set preset ........................... 13 5. Call preset........................... 13 6. Delete preset ..........................13 www.avonic.eu...
  • Page 3 7. Exposure mode selection ......................13 8. White balance mode selection ....................13 9. The camera OSD menu call ....................... 14 Maintenance ................15 Troubleshooting ................15 Contact ..................15 Appendix ..................16 Technical Data ........................... 16 Quick Installation Guide........................16 www.avonic.eu...
  • Page 4: Introduction

    Before cleaning, unplug the power cable. Use a soft, damp cloth to clean the device, do not use strong or abrasive detergent to clean as it will damage the device. • If you wish to dispose this product, please contact Avonic to obtain info about the take-back procedure. Package contents and Accessories...
  • Page 5: Features

    10 per channel. • PTZ and lens control speed can be adjusted through the control knob Product Description Top View 1. “AE AUTO” Automatic Exposure Mode “-BRIGHT+” Brightness priority Button “-IRIS+” Aperture priority dial button 2. “CAMERA” Camera channel button (1-5) www.avonic.eu...
  • Page 6: Back View

    13. “PTZ/ZOOM SPEED” change the control speed of camera 14. “POSITION” 1-10 keys, preset settings, set, call, delete preset. Or to choose camera from channel after pressing ADD button 15. Control joystick. Pan, tilt and lens focus of the camera. Back View www.avonic.eu...
  • Page 7: Installation

    1. Firmware upgrade connector (9-pin DSUB male) (TALLY not implemented in AV-CON300 model) 2. Camera control channel CH1-CH5 (RJ45) 3. 5-pin Phoenix interface (only CH1) 4. dip switch area 5. 12V DC power supply 6. Power switch Installation Connection Diagram...
  • Page 8: Connect The Camera

    RJ45 channels (CH1-CH5) The Avonic AV-CON300 comes with a single RS232 connecting cable with RJ45 plug to round head pin 8 plug). With this cable only 1 channel can be connected to the controller. This channel can control up to 7 (VISCA) or up to 10 (PELCO) cameras.
  • Page 9: Phoenix Connector

    4. RS232 TX (B) 5. RS232 RX (A) Connecting multiple cameras by RS232 The VISCA protocol supports up to 7 cameras and can be cascaded by connecting RS232-out from each camera to RS232-in of the following according to the picture: www.avonic.eu...
  • Page 10: Connecting Multiple Cameras By Rs485

    To connect multiple cameras by RS485, the cameras need to get attached to a 2-wire twisted pair bus that is terminated at both ends with a 120 Ω impedance terminator resistor to extinguish line reflections. The maximum distance from the bus to the camera or controller is 5 meters www.avonic.eu...
  • Page 11: Addressing Multiple Cameras

    Both the controller and the camera need to communicate over the same protocol and address. Tally/Upgrade connection Tally not implemented in AV-CON300 model. If any Firmware Update is advised, please contact Avonic for firmware image and update procedure. DIP switches Standard operating setting is all DIP switches OFF, except DIP7 is ON.
  • Page 12 Modify Password (use position keys to enter 4 digit password) 8. About device a. Hardware Version b. Software Version 9. Factory Reset Be careful: this IMMEDIATELY resets the controller 10. Rocker Reset Press the Zoom Rocker Button to Tele to the max and then press Reset www.avonic.eu...
  • Page 13: Operation

    Press the "WBC MODE" button to cycle the white balance modes ("WBC AUTO", "INDOOR", "OUTDOOR", "ONE PUSH", "ATW", "OUT", "MANUAL"); Rotate the "R" knob that triggers the manual white balance mode, which can adjust the depth of the red, "+" the red becomes darker, and the "red" becomes lighter; www.avonic.eu...
  • Page 14: The Camera Osd Menu Call

    TELE. To change a value of a menu setting, move the joystick to the left or the right. The Zoom Rocker to WIDE moves 1 level up in the menu. The IRIS button can also be used to select a menu item by turning right. Turn it to the left to move 1 level up. www.avonic.eu...
  • Page 15: Maintenance

    Initial Settings Check Advanced Checks Contact For any questions or suggestions, contact the reseller or the local distributor of Avonic. Find the local distributor on the website of Avonic. For the recent manual or datasheet, look at the Avonic website.
  • Page 16: Appendix

    Step 2. In the Controller Menu (press Menu, password 8888) select Channel 1. Make sure the camera communication protocol is set to VISCA on address 1 and baud rate 9600. See camera manual for reference. Step 3. Now it is possible to control the camera by the Avonic AV-CON300 camera controller. www.avonic.eu...