Set Up and
6
configuration
***SETUP****
1) Touch
to begin
setting up the thermostat.
SETUP
*CLOCK
3) Set the clock format,
time and date.

Wiring Diagrams

A) Sundial S-plan
V4043
C) Combi boiler
Receiver Box
Boiler*
* See boiler specifications for correct terminals
Manufactured for and on behalf of the Environmental and Energy Solutions Division of Honeywell
Technologies Sàrl, ACS-ECC EMEA, Z.A. La Pièce 16, 1180 Rolle, Switzerland by its Authorised
Representative Honeywell Inc.
SETUP
**LANGUAGE**
2) Select your language.
SETUP
CONFIGURE W
4) Touch
to finalise setup.
(
to setup using the App is
currently unsupported)
Receiver Box
1
2
Cylinder thermostat
V4043
Boiler
T1 T2
Once setup is completed, if you need to
change more settings go to the advanced
menu. To access the advanced menu
press
for 5 seconds.
In the advanced menu the following
settings can be adjusted:
Menu Item
LANGUAGE
SYSTEM TYPE
OPENTHERM
CYCLE RATE
MINIMUM ON TIME
HEAT RANGE
SCHEDULE OPTIONS
OPTIMISE
CLOCK
LOW LOAD CONTROL
TEMPERATURE OFFSET
BINDING
RESET
FAILSAFE
B) Sundial Y-plan
V4073A
Mid Position
zone valve
D) OpenTherm boiler
For other wiring
diagrams visit:
www.honeywelluk.com/
professional-zone/resource-centre/
Wiring Diagrams/
AM
*****230****
PM
Default
Options
0 = English, 1 = Français, 2 = Español
English
3 = Deutsch, 4 = Nederlands, 5 = Italiano
Heating only, Heating + Hot Water, Heating
Heat+HW
+ Cooling
-
OpenTherm boiler data when available
6
3, 6, 9 or 12
1 minute
1, 2, 3, 4 or 5 minutes
Min = 5.0ºC
Min: 5ºC to 21ºC, Max: 21ºC to 35ºC
Max = 35.0ºC
Daily
1 = Daily schedule, 2 = 5+2 days schedule
Opt. start OFF
Opt. start: 0 = off, 1 = on, 2 = Delayed start
Opt. stop OFF
Opt. stop: 0 = off, 1 = on
Format: 24h
Clock format: 1 = 12h, 2 = 24h
Time: --:--
Setup time and date
Date: 01/09/16
ON
0 = off, 1 = on
0.0ºC
1.5 ºC to 1.5ºC
-
Bind , check RF and clear bind.
-
Factory, schedule, WiFi and HomeKit reset
OFF
0 = off, 1 = on
Receiver Box
Boiler
Receiver Box
T1 T2
Boiler*
*1234
AM
PM
AM
PM
1
2
3
4
5
6
5 sec
1
2
Cylinder thermostat
For security
reasons: Route
this wiring
through conduit
or in the wall so it
is not accessible.