NOTICE
Adhere to the USB connection sequence
You will not be able to transfer a project to the HMI device if you do not adhere to the
connection sequence.
Observe the following sequence when connecting by USB:
1. HMI device
2. PC
USB host-to-host cable
You will not be able to transfer a project to the HMI device if you use the driver for the USB
host-to-host cable.
Use only the driver for the USB host-to-host cable that is included in the WinCC flexible
package.
Note
Point-to-point connection
Use a cross cable for a point-to-point connection. The HMI device and the PC can also be
subscribers in a local area network.
Connection via WLAN
In its factory state, the WLAN interface of the HMI device is disabled. Before you access the
HMI device from the configuration PC via WiFi, you need to appropriately configure the
access point and HMI device in infrastructure mode. An ad hoc wireless network is not
possible.
Restoring the factory settings
To update the operating system and reset the factory settings, you need to connect the HMI
device to the configuration PC via the RJ45 port. Connect a configuration PC directly to the
HMI device only as long as it is necessary. You can find additional information in the
"Restoring factory settings (Page 194)" section.
Wireless Teach Pendant F IWLAN V2
Operating Instructions, 08/2010, A5E02453837-01
PRELIMINARY II
1.7.2010
Mounting and connection
4.5 Connecting the HMI device