Controller Mode Is Set Incorrectly At System Setup; Boot Mode, Boot Sequence, And/Or Boot Sequence Retry Are Set Incorrectly; Bootable Virtual Disk Is In A Failed State; The Boot Order Is Incorrect For A Bootable Virtual Disk - Dell PowerEdge S130 User Manual

Table of Contents

Advertisement

Controller mode is set incorrectly at System Setup

1.
In the system startup, when the Dell Power-On Self-Test (POST) screen is displayed, press <F2> to enter the Dell Inc.
PowerEdge BIOS screen.
2.
Scroll to SATA Settings. Press <Enter> and ensure that the SATA Controller is set to RAID mode.
NOTE: While switching from RAID Mode to ATA Mode or AHCI Mode, there may be data loss.

Boot mode, boot sequence, and/or boot sequence retry are set incorrectly

1.
Turn on the system
2.
When the Dell POST screen is displayed, press <F2> to enter the Dell Inc. PowerEdge BIOS screen.
3.
Scroll to Boot Settings. Press <Enter> and ensure that Boot Mode is set to BIOS.
4.
Scroll to Boot Sequence. Press <Enter> and ensure that Hard drive C: is the first device listed.
5.
Scroll to Boot Sequence Retry. Ensure that the setting is Enabled.
6.
Press <Esc> to exit and continue booting.
NOTE: If changes are made at the Dell Inc. PowerEdge BIOS screen, a dialog box is displayed and asks you to save
your changes and then exit.

Bootable virtual disk is in a failed state

1.
Press <Ctrl><Alt><Del> to restart.
2.
After the system restart, press <Ctrl><R>. Check the status of the bootable virtual disk at the Virtual Disk field, or by
highlighting View Virtual Disks Details and pressing <Enter>.
3.
Check for missing or offline physical disks.

The boot order is incorrect for a bootable virtual disk

1.
When prompted at system startup, press <Ctrl><R> to access the PERC BIOS Configuration Utility.
2.
Check Virtual Disks and ensure that the bootable virtual disk is the first virtual disk listed.
3.
If required, use the Swap Two Virtual Disks option to reposition the virtual disks.
A Non-RAID virtual disk is no longer in the first position in the BIOS Configuration Utility
(<Ctrl><R>) list after the system is rebooted
NOTE: When booting from a Non-RAID virtual disk, creating a virtual disk in Dell OpenManage Server Administrator
changes the virtual disk order and displaces the bootable Non-RAID virtual disk from the first position. PERC S130 then
attempts to boot from the first virtual disk.
NOTE: A Non-RAID virtual disk can be created from Non-RAID physical disks (which are physical disks initialized by a
controller other than the PERC S130).
1.
When prompted at system startup, press <Ctrl><R> to access the BIOS Configuration.
2.
Check Virtual Disks and determine if the bootable Non-RAID virtual disk is no longer in the first position.
3.
Use the Swap Two Virtual Disks option to swap the virtual disks and place the bootable Non-RAID virtual disk in the first
position of the Virtual Disks field.
The BIOS Configuration Utility (<Ctrl><R>) option does not display
The BIOS Configuration Utility (<Ctrl><R>) option does not display if the PERC S130 mode is set incorrectly in the system BIOS.
For correct SATA Setting, see
Controller mode is set incorrectly at System Setup
.