Philips DVP3386K/93 Service Manual page 19

Hide thumbs Also See for DVP3386K/93:
Table of Contents

Advertisement

Distorted audio and loud noise
Distorted audio and
loud noise
Yes
Check the power supply voltages
+12VB and refa to the operation
amplifying are normal.
Yes
Check
whether
mutingtransistorQ22,Q
24, and Q26are normal
Yes
Check
whether
muting
transistor
Q23,Q25 are normal
Yes
Checking the U9 leads the
feet has no to break to
open
Yes
if the clock signal AL, AR
output by U1 are normal
Yes
Check whether the U1 or
U19powersupply normal
Yes
Replace U1 or U9
No
the
No
the
No
No
No
No
5-7
Check R9and R117
Replace
and
Q22,Q24
Q26
Replace Q23,Q25
Replace U1
SACLK waveform
SBCLK waveform SSLRCK waveform
Check U9
Trouble shooting chart