Security Function Ver. 1.02 Mar. 2016
8.5.1

Initialize method

1. Call the Service Mode to the screen.
See P.8
2. Touch [System 1].
3. Touch [Initialization].
4. Select [Clear All Data] or the clear item in [Clear Individual Data] and press the Start
key.
5. When "OK" is displayed, turn off the main power switch and turn it on again more than
10 seconds after.
NOTE
When the Clear All Data function has been executed, be sure to make the following
settings again.
• Since the CE password is reset to the default value, be sure to set once again a CE
password that meets the requirements of the Password Rules.
• Since the administrator password is reset to the default value, be sure to have the
administrator of the machine set once again an administrator password that meets
the requirements of the Password Rules.
• If you leave the site with the Service Mode setting screen being displayed, unau-
thorized changes could occur for any set values. When you finish the setting of
Service Mode, or if you have to leave the site by necessity when the Service Mode
has been set, be sure to touch [Exit] to the main screen.
• Since the Enhanced Security Mode is reset to "OFF," be sure to have the adminis-
trator set the Enhanced Security Mode to "ON."
29