This appliance must be connected by a competent person, using fixed wiring via a double
pole switched fused spur outlet, with a contact separation of 3mm at all poles.
Use a 3 amp fuse.
We recommend that the appliance is connected by a qualified electrician, who will comply
with the I.E.E. and local regulations.
Warning: This appliance must be earthed.
The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow = earth,
Blue = neutral,
Brown = live.
As the colours of the wires in the mains lead for the appliance may not correspond with the
coloured markings identifying the terminals in your spur box, proceed as follows:
1. The wire which is coloured green and yellow must be connected to the terminal marked
E (Earth) or coloured green.
2. The wire which is coloured blue must be connected to the terminal marked N (Neutral)
or coloured Black.
LOAD
3. The wire which is coloured brown must be connected to the terminal marked L (Live)
or coloured Red.
LOAD
If the supply cord is damaged, obtain a special cord from the Customer Care Centre
Helpline, which must be fitted by a qualified person.
Installing Your Cooker
Connect to the electricity supply
Typical example of a double
pole fused spur outlet
FUSE
Use a 3 amp fuse
Equipment you will need:
Flat bladed screw driver
ON
Live
N
L
SUPPLY
LOAD
~
13
N
LOAD
250
Neutral
Cable
49
Earth
L