Download Print this page

Bosch POPEX B299 Installation Manual page 2

Hide thumbs Also See for POPEX B299:

Advertisement

6 Confi guration
Use the following POPIT programming table to confi gure the POPIT switch block. Switches are designated as being "ON" or "OFF."
These are depicted in the table below by the following; ON = o, OFF = blank.
For example the swich settings for x09 looks like this: o,o,o,blank,o,o,blank (On,On,On,Off ,On,On,Off ).
Point number
Switch
0
1
2
3
4
5
B299
x00*
o
o
o
o
o
o
x01*
o
o
o
o
o
o
x02*
o
o
o
o
o
x03*
o
o
o
o
o
x04*
o
o
o
o
o
x05*
o
o
o
o
o
x06*
o
o
o
o
x07*
o
o
o
o
x08*
o
o
o
o
o
x09
o
o
o
o
o
x10
o
o
o
o
x11
o
o
o
o
x12
o
o
o
o
x13
o
o
o
o
x14
o
o
o
x15
o
o
o
x16
o
o
o
o
o
x17
o
o
o
o
o
x18
o
o
o
o
x19
o
o
o
o
x20
o
o
o
o
x21
o
o
o
o
x22
o
o
o
x23
o
o
o
x24
o
o
o
o
x25
o
o
o
o
x26
o
o
o
x27
o
o
o
x28
o
o
o
x29
o
o
o
x30
o
o
x31
o
o
x32
o
o
o
o
o
x33
o
o
o
o
o
x34
o
o
o
o
x35
o
o
o
o
x36
o
o
o
o
x37
o
o
o
o
x38
o
o
o
x39
o
o
o
x40
o
o
o
o
x41
o
o
o
o
x42
o
o
o
x43
o
o
o
x44
o
o
o
x45
o
o
o
x46
o
o
x47
o
o
x48
o
o
o
o
x49
o
o
o
o
* Not available for use on B299 at address 0.
Point number
Switch
0
1
2
3
6
B299
o
x50
o
o
x51
o
o
o
x52
o
o
x53
o
o
o
x54
o
o
x55
o
o
o
x56
o
x57
o
o
x58
o
x59
o
o
x60
o
x61
o
o
x62
o
x63
o
o
x64
o
o
o
x65
o
o
o
o
x66
o
o
o
x67
o
o
o
o
x68
o
o
o
x69
o
o
o
o
x70
o
o
o
x71
o
o
o
o
x72
o
o
x73
o
o
o
x74
o
o
x75
o
o
o
x76
o
o
x77
o
o
o
x78
o
o
x79
o
o
o
x80
o
o
x81
o
o
o
x82
o
o
x83
o
o
o
x84
o
o
x85
o
o
o
x86
o
o
x87
o
o
o
x88
o
x89
o
o
x90
o
x91
o
o
x92
o
x93
o
o
x94
o
x95
o
o
x96
o
o
x97
o
o
o
x98
o
o
x99
o
o
* Not available for use on B299 at address 0.
7 | Certifi cations
Region
Certifi cation
US
UL 365 - Police Station Connected Burglar Alarm Units and
Systems
UL 609 - Local Burglar Alarm Units and Systems
4
5
6
UL 636 - Holdup Alarm Units and Systems
o
o
UL 864 - Control Units and Accessories for Fire Alarm Systems
o
UL 985 - Household Fire Warning System Units
o
o
UL 1023 - Household Burglar-Alarm System Units
o
o
UL 1076 - Proprietary Burglar Alarm Units and Systems
UL 1610 - Central Station Burglar Alarm Units
o
o
o
ANSI/SIA CP-01:2010
o
o
CSFM - California Offi ce of The State Fire Marshal
o
o
FCC Part 15 Class B
o
CA
Canada CAN/ULC S303 - Local Burglar Alarm Units and Systems
o
o
CAN/ULC S304 - Signal Receiving Centre and Premise Alarm
o
Control Units
o
ULC-S545 - Residential Fire Warning Alarm Systems Control
units
o
o
o
ULC-ORD C1023 - Household Burglar Alarm System Units
o
o
ULC-ORD C1076 - Proprietary Burglar Alarm Units and Systems
o
o
ICES-003 - Digital Apparatus
o
o
o
o
8 | Specifi cations
o
Dimensions
2.9 in x 5.0 in x 0.6 in (73.5 mm x 127 mm x 15.25
o
o
o
mm)
o
o
Voltage (input)
12 VDC
o
o
Current
Standby: 35 mA + total device current
Alarm: 35 mA + total device current
o
Operating temperature
0°C to +50°C (+32°F to +122°F)
o
o
Relative humidity
5% to 93% at +32°C (+90°F) non-condensing
o
Terminal wire size
12 AWG to 22 AWG (2.0 mm to 0.65 mm)
o
SDI2 wiring
Maximum distance - wire size (unshielded wire
only): 200 ft (60 m) - 22 AWG (0.65 mm), 500 ft
o
o
o
(152 m) - 18 AWG (1.02 mm)
o
o
POPIT loop wiring
Maximum wire length: 1800 ft (548 m) 22 AWG
o
o
(0.65 mm), 4497 ft (1370 m) 18 AWG (1.02 mm)
o
Compatibility
Control panel: B9512G/B9512G-E (6 modules),
o
o
B8512G/B8512G-E (1 module). (Refer to the con-
o
trol panel installation document for the number of
supported devices.)
o
POPIT devices: D9127U/T, ZX776Z/ZX794Z PIR,
o
o
o
ZX835 TriTech, ZX935Z/ZX938Z PIR, ZX970 TriTech,
D278S 12V smoke base, D298S 24V smoke base,
o
o
F220-B6PM popit smoke (master), F220-B6PS
o
o
popit smoke base
o
o
o
o
o
Copyright
o
o
o
This document is the intellectual property of Bosch Security
o
o
Systems, Inc. and is protected by copyright. All rights reserved.
o
o
Trademarks
o
All hardware and software product names used in this document
are likely to be registered trademarks and must be treated
accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and
refer to the Bosch Security Systems, Inc. website at http://
www.boschsecurity.com/datecodes/.
POPEX module
B299
en Installation Guide
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
© 2016 Bosch Security Systems, Inc.
F.01U.300.043 | 06 | 2016.01

Advertisement

loading