Wall/Rack Mount the SL2100 System

4b- Rack Mount the SL2100 system

Installation Considerations:
If the system requires two or three chassis then each chassis will require a shelf plate within the 19 inch
rack, must be space above each chassis for heat ventilation.
Do not stack two or three chassis per one shelf plate.
1
Use the rack
mount shelf
supplied by NEC.
rd
3
party shelves
may block the side
ventilation and do
not provide any
securing method
! Ensure 44.5mm
space above each
chassis for
ventilation. The
shelf is oversize
(100mm high) to
ensure space is
provided.
Confirm the
location of the
rack mount shelf
and fit the four
cage nuts supplied
with the shelf
Fit the chassis into
the rack mount
shelf and secure
with the screw
supplied.
Fit the rack mount
shelf + chassis
into the 19 inch
rack and secure
the shelf with the
four screws
supplied
Quick Install Guide – SL2100 with Analogue Trunks rev 1.1
3U space will be required for each KSU.
Rack mount shelf requires 448mm x 337mm x 100mm (W x D x H) within the rack.
The AC power cable enters at the rear of the chassis, allow ~60mm for space at the
rear.
Ventilation is required above the chassis.
You may need to connect the AC power cable and Earth Ground cable to the rear of
the chassis prior to installing into the rack if you do not have sufficient space/access
to do this afterwards.