Electrical

This shaper must be properly set up before it is safe
to operate. DO NOT connect this shaper to the power
source until instructed to do so in the "Test Run"
portion of this manual.
220V/440V 3-Phase
Operation
The Model W1807 is prewired for 220V 3-phase operation,
but may be rewired for 440V 3-phase operation (see Page
11).
This machine must be hardwired to a locking shutoff
switch by a qualified electrician. Hardwiring involves a
permanent installation with conduit runs that can only be
accomplished safely by a qualified electrician. As always,
observe all applicable electrical codes when connecting
this machine to power.
This machine must be grounded! Verify the ground before
connecting this machine to the power source.

Electrical Specifications

Voltage
Amp Draw
220V
30
440V
15
Model W1807 7
ELECTRICAL
Min. Circuit Size
Connection
40A
Hardwire
20A
Hardwire
HP Heavy-Duty Industrial Tilting Spindle Shaper
1
2
Figure 1. Locking shutoff switch.
Attempting to connect this machine to
the power source without a qualified
electrician greatly increases the risk
of electrocution, fire, or machine
damage.
Cord
Conduit Setup
Conduit Setup
-10-
Extension Cord
N/A (Hardwire Only)
N/A (Hardwire Only)

Advertisement

Table of Contents
loading

Table of Contents