Panasonic AFP7CPS Series User Manual page 35

Communication cassette ethernet type fp7-series, cpu unit, extension cassettes ethernet x 1ch type
Table of Contents

Advertisement

KEY POINTS
Connection request will be performed when data transfer is executed.
Please execute master communication command after confirming the
connection status flag (X30) is OFF. When a connection successfully
established, connection status flag (X30) turns ON. If a connection failed,
connection status flag (X30) stays OFF and TCP client connection failure
flag (X32) turns ON. Please reconfirm the conditions of destination or
connection.
If it needs to continue data transfer between the same connected
equipment , please execute master communication command after
confirming the connection status flag (X30) is ON.
Timeout value of respons reception for AFP7CCET1 is the same as
connection termination timeout during no communication. Set the timeout
of SEND/RECV instruction longer than the timeout during no
communication to judge the timeout of response reception. Enter the "Time
setting" filed of "CPU Configuration" in the "FP7 configuration" dialig box
of FPWIN GR7.
 UDP Client mode
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
4.3 Example of User connection (MEWTOCOL)
Parameter
Protocol Mode
Action Mode
Communication
Mode
Send type
Destination IP
Address
Destination Port
No.
Source Port No.
Timeout
(Note):
The parameter "IP Address" is not
available, if BROADCAST is selected.
Default
UDP
Client Mode
MEWTOCOL
UNICAST
/BROADCAST
(Note1)
192.168.1.100
9094
9095
15 sec