7
Monitor Name (13 characters max.)
3.12
Hot-key definition
Any deviation between document and sample, please refer to Philips approved sample.
3.13 Smart contrast (Dynamic contrast ratio)
Smart Contrast is a kind of dynamic backlight control.
This function changes panel backlight dynamically according to the frame brightness histogram.
At least the minimum contrast ratio has to be > 6000:1
4
Visual characteristics
4.1
Test conditions
Unless otherwise specified, this specification is defined
under the following conditions.
(1) Input signal : As defined in 3.3, 1366*768
(2) Luminance setting : controls to be set to 300 nits with
(3) Warm up: more than 30 minutes after power on with signal supplied.
(4) Ambient light: 400 -- 600 lux.
(5) Ambient temperature: 20 ± 5 C
4.2
Brightness
To follow Panel specification.
4.3
Image size
Actual display size : Refer to 2.1 LCD PANEL spec.
4.4
Brightness uniformity
Set contrast at 100% and turn the brightness to get average above 300 nits
at centre of the screen.
Apply the Fig 1, it should comply with the following formula:
Where B_max =Maximum brightness
1.0
Rev :
2008/12/31
Date :
ph il ips
non-interlaced mode (1366*768@60Hz 85.5MHz), signal
sources must have 75 ohm output impedance.
full screen 100 % duty cycle white signal
B_min
B_max
B_min = Minimum brightness
160E1
Type
:
PHILIPS
Brand :
Philips 160EL
X 100% > 75% (Follow panel spec.)
15.6" Wide LCD Monitor
Page :