Regency Zero Clearance Direct Vent Gas Fireplace P121/P131-LP2 Specifications

Zero clearance direct vent gas fireplace

Advertisement

Quick Links

P121 - P121LC/RC - P131 Zero Clearance Direct Vent Gas Fireplace
Model
P121/P131-NG2
Fuel Type
Natural Gas
Minimum Supply Pressure
5" W.C. (1.25 kPa)
Manifold Pressure - High
3.8" W.C. (0.95 kPa)
Manifold Pressure - Low
1.1" W.C. (0.27 kPa)
Orifi ce Size
#31 DMS
Minimum Input
20,500 BTU/h (6.01 kW)
Maximum Input
40,000 BTU/h (11.72 kW)
Vent Sizing
4" Inner / 6-5/8" Outer
Approved Venting Systems
Flex Vent Systems:
Rigid Pipe Vent Systems:
M
O
N
P
Electrical
Gas Line
BACK
Inlet
Inlet
P121RC Right Corner
B
G
A
Unit Dimensions
Description
A
Front Face Width
B
Total Firebox Width
C
Front Face Height
D
Height w/ Standoff
E
Unit Depth
F
Top Offset Depth
G
Inset to Standoff
If the provided 3" extension trim is not installed the P121(LC/RC)/
P131 must be installed with non-combustible facing up to 8" above
the fi replace. Otherwise combustible facing may be used above the
extension trim.
Please refer to Page 11 (Exterior Vent Terminations)
for additional guidelines on vent locations.
June 2007 Regency Product Specifi cations Book
Gas Fireplaces
P121/P131-LP2
Propane
12" W.C. (3.00 kPa)
11" W.C. (2.74 kPa)
2.9" W.C. (0.72 kPa)
#50 DMS
20,600 BTU/h (6.04 kW)
39,000 BTU/h (11.43 kW)
4" Inner / 6-5/8" Outer
FPI AstroCap™ Flex Vent
Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent
Security Secure Vent®
Selkirk Direct-Temp.
P121 See Thru
P131 Pier
P121LC Left Corner
F
D
C
E
P121
P121LC/RC
P131
43-1/2"
41-1/2"
41-1/2"
(1105mm)
(1054mm)
(1054mm)
46-1/4"
44-1/2"
44-1/2"
(1175mm)
(1130mm)
(1130mm)
36" (914mm)
36" (914mm)
36" (914mm)
42" (1067mm)
42" (1067mm)
42" (1067mm)
26-13/16"
25" (635mm)
25" (635mm)
(681mm)
21-1/8"
21-1/8"
21-1/8"
(537mm)
(537mm)
(537mm)
4-3/4"
4-3/4"
3" (76mm)
(121mm)
(121mm)
Greyed out framing will not apply to all units.
Please refer to the manual.
I
H
K
Framing Dimensions Description
H
Framing Width
**
**
I
Framing Height
**
**
J
Framing Depth
K
Vent Centerline Height
L
Framed Chase Ceiling
M
Electrical Inlet Height
N
Electrical Inlet Inset
O
Gas Connection Height
P
Gas Connection Inset
** Refer to the manual for variations effected by fi nishing material
thickness.
P121-P131 Gas Fireplace
L
J
8"
Top of
Non-Combustible
Unit
Material *
Combustible
Material
3"
Extension
Trim
P121
P121LC/RC
P131
45"
45"
46-3/4"
(1187mm)
**
**
(1143mm)
(1143mm)
42-1/2"
42-1/2"
42-1/2"
(1080mm)
(1080mm)
(1080mm)
26-13/16"
**
**
25" (635mm)
25" (635mm)
(681mm)
42-13/16" (1072mm)
48-1/4" (1226mm)
2" (51mm)
2" (51mm)
2" (51mm)
11-3/8"
13-5/16"
11-3/8"
(289mm)
(338mm)
(289mm)
1-11/16"
1-11/16"
1-5/8" (41mm)
(43mm)
(43mm)
11-1/2"
11-1/2"
11-1/2"
(292mm)
(292mm)
(292mm)
69

Advertisement

loading

Summary of Contents for Regency Zero Clearance Direct Vent Gas Fireplace P121/P131-LP2

  • Page 1 fi replace. Otherwise combustible facing may be used above the extension trim. Please refer to Page 11 (Exterior Vent Terminations) for additional guidelines on vent locations. June 2007 Regency Product Specifi cations Book P121/P131-LP2 Propane 12” W.C. (3.00 kPa) 11”...
  • Page 2: Framing And Finishing

    Note: If desired a non-combustible mantel may be installed at a lower height. Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour. June 2007 Regency Product Specifi cations Book P121(LC/RC)/131 36” (914mm) Clearance Dimension 2-1/2”...
  • Page 3: Snorkel Terminations

    S.S. screws #8 x 1-1/2” drill point, (4) Notes: Liner sections should be continuous without any joints or seams. Only Flex pipe purchased from Regency may be used for Flex installations. Horizontal sections must be supported every 3 feet. Alternate Horizontal Termination Caps June 2007 Regency Product Specifi...
  • Page 4: Rigid Pipe Venting

    Total horizontal sections must not 2’ Min. 4’ Max. exceed 8 feet. 3’ Min. 6’ Max. Minimum of 1 foot between 90° elbows is required. 4’ Min. 8’ Max. IMPORTANT 45 Elbow Rigid Pipe Adapter 1-1/2” (38mm) June 2007 Regency Product Specifi cations Book...
  • Page 5 Minimum of 1 foot between 90° elbows is required. 8’ Max. 4’ Min. June 2007 Regency Product Specifi cations Book P121-P131 Gas Fireplace Vertical Venting with Three (3) 90° Elbows - Initial vertical section. Two 45° elbows = One 90° elbow...
  • Page 6: Venting Arrangements - Horizontal Terminations

    2’ Min. 6’ Max. not exceed 17 feet. 3’ Min. 9’ Max. Minimum of 1 foot between 90° elbows is required. 4’ Min. 12’ Max. 5’ Min. 15’ Max. 6’ Min. 17’ Max. June 2007 Regency Product Specifi cations Book...
  • Page 7 Minimum of 1 foot between 90° elbows is required. 8’ Max. 5’ Min. 12’ Max. June 2007 Regency Product Specifi cations Book P121-P131 Gas Fireplace Horizontal Venting with Three (3) 90° Elbows - Initial vertical section. Two 45° elbows = One 90° elbow...

This manual is also suitable for:

Zero clearance direct vent gas fireplace p121/p131-ng2P121-ng2P131-ng2P121-lp2P131-lp2