fi replace. Otherwise combustible facing may be used above the extension trim. Please refer to Page 11 (Exterior Vent Terminations) for additional guidelines on vent locations. June 2007 Regency Product Specifi cations Book P121/P131-LP2 Propane 12” W.C. (3.00 kPa) 11”...
Note: If desired a non-combustible mantel may be installed at a lower height. Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour. June 2007 Regency Product Specifi cations Book P121(LC/RC)/131 36” (914mm) Clearance Dimension 2-1/2”...
S.S. screws #8 x 1-1/2” drill point, (4) Notes: Liner sections should be continuous without any joints or seams. Only Flex pipe purchased from Regency may be used for Flex installations. Horizontal sections must be supported every 3 feet. Alternate Horizontal Termination Caps June 2007 Regency Product Specifi...
Total horizontal sections must not 2’ Min. 4’ Max. exceed 8 feet. 3’ Min. 6’ Max. Minimum of 1 foot between 90° elbows is required. 4’ Min. 8’ Max. IMPORTANT 45 Elbow Rigid Pipe Adapter 1-1/2” (38mm) June 2007 Regency Product Specifi cations Book...
Page 5
Minimum of 1 foot between 90° elbows is required. 8’ Max. 4’ Min. June 2007 Regency Product Specifi cations Book P121-P131 Gas Fireplace Vertical Venting with Three (3) 90° Elbows - Initial vertical section. Two 45° elbows = One 90° elbow...
2’ Min. 6’ Max. not exceed 17 feet. 3’ Min. 9’ Max. Minimum of 1 foot between 90° elbows is required. 4’ Min. 12’ Max. 5’ Min. 15’ Max. 6’ Min. 17’ Max. June 2007 Regency Product Specifi cations Book...
Page 7
Minimum of 1 foot between 90° elbows is required. 8’ Max. 5’ Min. 12’ Max. June 2007 Regency Product Specifi cations Book P121-P131 Gas Fireplace Horizontal Venting with Three (3) 90° Elbows - Initial vertical section. Two 45° elbows = One 90° elbow...