  • Page 1 3M Occupational Health & Environmental Safety Division AcoustiCal AC-300 Calibrator Precise,Simplistic Calibration AcoustiCal User Manual...
  • Page 2: Intended Use

    AcoustiCal, or reference meter with similar specifications/accuracy. Intended Use: The AcoustiCal is intended to calibrate precision Class/Type 1 and Class/Type 2 instruments with a microphone input. Consult your company’s safety professional for local standards, or call 3M at 1-800-243-4630. AcoustiCal User Manual...
  • Page 3: Table Of Contents

    Coupler volume coefficient ................... 6 Electromagnetic emissions and susceptibility ............6 Background acoustic level ..................6 Power ........................6 3M Quest Service ...................... 7 Warranty ........................8 Figures Figure 1: Operating the calibrator ................1 Figure 2: Re-insert battery door ................2 Figure 3: Closing battery door ...................
  • Page 4: Acoustical

    / AcoustiCal AcoustiCal Models The 3M AcoustiCal AC-300 is an acoustic calibrator for calibrating precision Class/Type 1 as well as general purpose Class/Type 2 sound level meters and noise dosimeters. The AC-300 produces two signals either 250 Hz or 1000 Hz at a sound pressure level of 114.0 dB.
  • Page 5: Battery

    Battery Battery A 9-volt battery is used to supply power to the calibrator. Low Battery At a low battery condition, the low battery indicator will appear. If the battery level becomes too low, the calibrator will power off. Changing the battery The battery door is located on the top of the calibrator.
  • Page 6: Performing A Calibration

    Performing a calibration Performing a calibration A microphone is sensitive to temperature and pressure changes. Calibrating before taking measurements assures that your level measurements are accurate for the current environment; and performing a calibration after use allows you to verify the integrity of both the calibrator and the sound level meter.
  • Page 7: Factory Service On The Calibrator

    3M Quest Technologies recommends checking the performance and precision of your calibrator on an annual basis by sending it to a factory-authorized service center. The AcoustiCal is calibrated at Quest Technologies laboratory, a 3M company, with a Type L standard microphone and with special instrumentation traceable to NIST. The calibrators are very stable;...
  • Page 8: Specifications

    Specifications Specifications Conformance standards ANSI S1.40-1983 (R2006): Specifications and Verification Procedures for Sound Calibrators IEC 60942 (2003-01): Electroacoustics, Sound Calibrators CE, RoHS, WEEE, C-Tick Physical characteristics Size 10 cm x 5.8 cm x 4.6 cm (Length x Width x Thickness) 3.9”...
  • Page 9: Storage Environmental Conditions

    Specifications Storage environmental conditions Storage temperature range -20°C to 65°C (-4 °F to 149°F) with battery removed. Storage humidity range 0% to 90% non-condensing Coupler volume coefficient No effect until overload occurs. Electromagnetic emissions and susceptibility Emission better than CISPR 22, Class/Type B susceptibility better than 10 V/m, 150 kHz to 1GHz.
  • Page 10: 3M Quest Service

    3M Quest Service 3M Quest Service Should your Quest Technologies, a 3M company, equipment need to be returned for repair or for recalibration, please contact the service department at the following numbers or access the online form via the website.
  • Page 11: Warranty

    Warranty Warranty Quest Technologies, a 3M company, warrants our instruments to be free from defects in materials and workmanship for one year under normal conditions of use and service. For United States customers, we will replace or repair (our option) defective instruments at no charge, excluding batteries, abuse, misuse, alterations, physical damage, or instruments previously repaired by other than Quest Technologies, a 3M company.