Parameter
MonitorConnection TIME
LocaleIDs
5.3.4

UDT752 UAUserIdentityToken

UAUserIdentityToken
The following table shows the meaning of the user authentication data that supplies the
UserIdentityToken parameter of the UDT "UASessionConnectInfo".
Table 5- 3
Parameter
UserIdentity
TokenType
TokenParam1
TokenParam2
5.4

FB231 UA_NamespaceGetIndex

5.4.1

Function and call interface - UA_NamespaceGetIndex

Function of the block
With the block you fetch the name space index of the name space URI of the connected UA
server.
CP 443-1 OPC UA
Operating Instructions, 01/2017, C79000-G8976-C427-02
S7 data type
Range of val-
ues
5000 ..
86 400 000
ARRAY[1..5]
Examples:
of String[6]
en-US, de-DE,
zh-CHS ...
Parameters of UDT UAUserIdentityToken
S7 data type
Range of val-
ues
WORD
0, 1
STRING
1 .. 254 char-
acters
STRING
1 .. 254 char-
acters
Programming the OPC UA client blocks
5.4 FB231 UA_NamespaceGetIndex
Meaning
Connection monitoring time (milliseconds)
Time without data traffic after which the client
checks the connection to the server by send-
ing a frame.
Default setting: 15000 (15 seconds)
Optional language and regional identifier acc.
to RFC 3066.
0 = no or unknown LocaleID.
Meaning
0 = No authentication
1 = Authentication
When the communications partner (server)
demands authentication with a user name and
password, set this parameter to 1 and the two
following according to the requirements of the
server.
User name
Password