Emerson FB1100 Flow Computer Instruction Manual
D301752X012
July 2017
Figure 2-10: Transmitter with Traditional Flange and Optional Flange Adapters
Use the following bolt installation procedure:
1.
Carbon steel bolts do not require lubrication. Stainless steel bolts are factory-coated with a
lubricant to ease installation. Do not apply any additional lubricant when installing either
type of bolt.
2.
Finger-tighten the bolts.
3.
Torque the bolts to the initial torque value using a crossing pattern. See
torque value.
4.
Torque the bolts to the final torque value using the same crossing pattern. See
final torque value.
5.
Verify that the flange bolts protrude through the sensor module before applying pressure.
Table 2-3: Torque Values for the Flange and Flange Adapter Bolts
Bolt
Material
Carbon
Steel (CS)
Stainless Steel
(SST)
18
Head markings
Table 2-3
for initial
Table 2-3
Initial Torque
Final Torque
300 in. -lbs.
650 in. -lbs.
(73.4 N m)
(33.9 N m)
150 in. -lbs.
300 in. -lbs.
(16.9 N m)
(33.9 N m)