Examples Of Safety Measures; Cr750 Controller - Mitsubishi Electric CR750-D Instruction Manual

Industrial robot
Hide thumbs Also See for CR750-D:
Table of Contents

Advertisement

2Unpacking to installation

2.2.9 Examples of safety measures

Two emergency-stop input circuits are prepared on the user wiring terminal block of the controller. Create a cir -
cuit as shown below for safety measures. In addition, the figure shows the normal state which is not in the emer -
gency stop state.
[Caution] Since we have omitted the information in part because of explanation, there is the section different
from the product. Also refer to
explanation]"
[Note] ・ In the emergency-stop related wiring by the customer, if the coil (is not the contact points) of the relay
prepared by the customer is connected to the controller, please be sure to implement the measure
against the noise by the customer in the coil section. And, please also take the lifetime of noise sup -
pression parts into consideration.
・ Electric specification of the emergency-stop-related output terminal: 100mA/24V or less.
・ In the customer's system, do not ground the + side of 24V power supply prepared by customer for con -
nect to the controller. (related with emergency stop and parallel input/output) If it connects with the
controller under the condition that the + side is grounded, it will lead to failure of controller.

(1) CR750 controller

<Wiring example 1>: Connect the emergency stop switch of peripheral equipment to the controller.
The power supply for emergency stop input uses the power supply in the controller.
<Operation of the emergency stop>
Controller
OP Emergency
OP非常停止
stop button
ボタン
*6)
TB Emergency
TB非常停止
stop button
ボタン
*3)
Input
入力
detection
検知
circuit
回路
Internal emergency stop
circuit
*3) The T/B emergency stop button connected with the controller.
*4) Emergency stop input relay.
*5)
Refer to the Standard specification manual or Special specification manualfor the enabling device.
*6) The emergency stop button of the robot controller. (Only specification with the operation panel.)
*7) The emergency stop input detection relay is used the controller's internal safety relay control. If the
emergency stop input detection relay is switched OFF, emergency stop is detected and the safety relay is also
switched OFF.
Fig.2-26 : Example of safety measures (Wiring example 1)
2-42 Installation
and
Page 23, "2.2.7 Connecting the external emergency
If the emergency stop switch of peripheral equipment is pushed, the robot will also be in the emergency
stop state.
Power supply in the
robot controller 24V
内部電源 24V
*4)
10μF
RA
*7)
Safety relay
安全リレー
内部非常停止回路
Page 57, "(4) External emergency stop connection [supplementary
CNUSR11/CNUSR12
1
Not connected
短絡
2
3
4
5
Short circuit
短絡
6
(Short-circuited)
7
Door switch input
ドアスイッチ入力
8
RA
9
10
RA
Enabling
イネーブリング
device
デバイス
*5)
13
}
Emergency stop output
非常停止出力
14
11
}
Mode output
モード出力
12
*2)
CNUSR2
16/17
}
Error output
エラー出力
41/42
stop".
Emergency stop switch
(2- contact type)
*1)
Safety
安全柵のドア
fence door
*1) Each of the connectors,
CNUSR11 and CNUSR12, are
assigned with the same pin
number, creating two systems for
each terminal. It is absolutely
necessary to connect the two
systems.
*2) You can see in the diagram that
connector CNUSR2 has two
terminals and two systems (16/
17 indicates two terminals at pin
number 16 and pin number 17).
It is absolutely necessary to
connect the two systems.
非常停止スイッチ
(2接点タイプ)
Peripheral
周辺装置
equipment