1. Overview
Using mechanical and fan for high efficient heat dissipation and pump laser install in
the aluminium box, achieve the perfect and stable circuit of optic power output and
controlling circuit of thermoelectric refrigeration device of pump laser assure the best
quality for user and stable working for a long time.
The output optical power can be adjusted through the button in the panel or the
software, the extend range is 0.5dBm, and minus range is 4dBm.
Standard RJ 45 port for remote control, we can provide output contract and web
manager for choice, and also plug-in SNMP hardware can be reserved for update.
The RS-232 standard connector makes it is possible to manage on line and monitor
in other place.
Adopts America JDSU, Bookham and Japan FERETEC Pump laser,and the
Erbium-Doped fiber is America OFS.
Front panel VFD or LED displays the working condition of the machine and the fault
warning.
Dual power and hot plug power supply for choice and it can work with the voltage
from 90V to 265V or -48V DC.
The max output power is 27dBm(500mW).
2. Installation

2.1 Before Installation

2.1.1 Please check if there is damage in outside of the machine.
2.1.2 Please check the spare part and the certification are complete or not,if not, please
contact the seller.
2.2 Installation
2.2.1 Please keep at least 1.75 inches(4.5cm) space for cooling when the machine
installed with other machines.
2.2.2 Please check power supply socket and the grounding of the power supply,the
grounding impedance should ≤4Ω, 220V power supply should be with three cables and
the grounding cable should be in the middle, Unfitted grounding will damage the device or
- 4 -