Siemens SIMATIC ET 200SP Manual page 105

Analog input module ai energy meter 400vac st 6es7134-6pa01-0bd0
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Byte
Measured variable
102...105
Active power L2
106...109
Active power L3
110...113
Total active power L1L2L3
114...117
Phase angle L1
118...121
Phase angle L2
122...125
Phase angle L3
126...129
Total apparent energy L1L2L3
130...133
Total reactive energy L1L2L3
134...137
Total active energy L1L2L3
138...141
Total reactive energy inflow L1L2L3
142...145
Total reactive energy outflow L1L2L3
146...149
Total active energy inflow L1L2L3
150...153
Total active energy outflow L1L2L3
154...161
Total apparent energy L1L2L3
162...169
Total reactive energy L1L2L3
170...177
Total active energy L1L2L3
178...185
Total reactive energy inflow L1L2L3
186...193
Total reactive energy outflow L1L2L3
194...201
Total active energy inflow L1L2L3
202...209
Total active energy outflow L1L2L3
Procedure
Data record 142 is located on the AI Energy Meter 400VAC ST. Use SFB "RDREC" to read
out the data record from the module. This system function block is stored in the STEP 7
library.
Measured values in STEP 7 as of V5.5
Measured values are represented as negative values in STEP 7 as of V5.5 if the value range
of the integer format (32767 dec) is exceeded. This is not an error in the measured value.
Solution: Select hexadecimal representation.
Conversion of 64-bit floating-point numbers
If you cannot process 64-bit floating-point numbers in your automation system, we
recommend conversion to 32-bit floating-point numbers. Note the conversion can cause loss
of accuracy. For a description of the conversion of the 64-bit floating-point numbers (data
type LREAL) into 32-bit floating-point numbers (data type REAL) please refer to the Internet
(http://support.automation.siemens.com/WW/view/en/56600676).
Analog input module AI Energy Meter 400VAC ST (6ES7134-6PA01-0BD0)
Manual, 10/2017, A5E36061895-AB
E.2 Measured value data record for base measurements (DS 142)
Data
type
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
REAL
LREAL
LREAL
LREAL
LREAL
LREAL
LREAL
LREAL
Measured value data records
Unit
Value range
W
-3.0 x 10
... +3.0 x 10
9
W
-3.0 x 10
... +3.0 x 10
9
W
-3.0 x 10
... +3.0 x 10
9
°
0.0 ... 360.0
°
0.0 ... 360.0
°
0.0 ... 360.0
VAh
0.0 ... 3.4 x 10
38
varh
-3.4 x 10
to +3.4 x 10
38
Wh
-3.4 x 10
to +3.4 x 10
38
varh
0.0 ... 3.4 x 10
38
varh
0.0 ... 3.4 x 10
38
Wh
0.0 ... 3.4 x 10
38
Wh
0.0 ... 3.4 x 10
38
VAh
0.0 ... 1.8 x 10
308
varh
-1.8 x 10
to +1.8 x 10
308
Wh
-1.8 x 10
to +1.8 x 10
308
varh
0.0 ... 1.8 x 10
308
varh
0.0 ... 1.8 x 10
308
Wh
0.0 ... 1.8 x 10
308
Wh
0.0 ... 1.8 x 10
308
Mea-
sured
value
ID
14
9
15
9
34
9
61178
61198
61218
204
206
38
205
38
202
203
200
201
214
216
308
215
308
212
213
210
211
105