Download Print this page

Fetco ZURICH CBS-2121 Users Manual And Operator Instructions page 6

Pour over coffee brewer
Hide thumbs Also See for ZURICH CBS-2121:

Advertisement

This section is for professional use only for installation, adjustment and service.
Danger of fire or electric shock, do not open panels. No user serviceable parts inside.
All adjustments and service to be performed by authorized professional personnel
To adjust the temperature for high altitude installation:
Thermostatic control is factory set to the maximum temperature: 200°F and is adjustable to the lowest setting
of 180°F. The capillary thermostat is rated within 5% of this range.
To correct for boiling at high altitudes the thermostat may be adjusted to a lower setting.
1. Unplug the power cord.
2. Remove the back cover.
3. Locate the thermostat:
4. Turn the adjustment to the left to decrease the temperature
{Minimum is 180°F/Maximum is 200°F}
5. Reinstall back cover and plug into the power outlet.
6. Brew, refill and re-check the temperature after the "READY" light is on.
Thermostat adjustment
Left to lower & Right to raise.
Make small, incremental changes.
Check temperature after "READY" light is on.
NOTE: at some high elevations it may be required to set thermostat all the
way down, and raise it back only slightly to compensate for boiling.
Adjustment is accurate to +/- 5%.
Wiring Diagram CBS-2121 Manual Fill Coffee Brewer
LIMING
To prevent liming problems in tank fittings remove sprayhead and insert deliming spring all the way into the
tank. When inserted into tank properly, no more than ten inches of the spring should be visible at the
sprayhead fitting. Saw back and forth five or six times. This will keep fittings open and clear of lime. In hard
water areas this should be done everyday. This process takes approximately one minute. In all areas the
sprayhead should be cleaned at least once a week. Where bad liming has already occurred, a new complete
tank assembly may be installed. The tank may be changed in approximately 5-10 minutes time.
500 152
1000 305
2000 610
2500 762
3000 914
3500 1067
4000 1219
4500 1372
5000 1524
5500 1676
6000 1829
6500 1981
7000 2134
7500 2286
8000 2438
8500 2591
6
Chart to correct for altitude for boiling point
in tank water temperature.
Suggested
Boiling
Suggested
[ft]
[m]
Setting[°F]
point[°F]
Setting[°C]
0
0
205
212.0
96
205
211.0
96
200
210.1
93
200
208.1
93
200
207.2
93
200
206.2
93
197
205.3
92
195
204.3
91
194
203.4
90
194
202.4
90
193
201.5
89
192
200.6
89
191
199.6
88
190
198.7
87
188
197.8
86
187
196.9
86
185
196.0
85
P155
Boiling
point [°C]
100.0
99.5
98.9
97.8
97.3
96.8
96.3
95.7
95.2
94.7
94.2
93.6
93.1
92.6
92.1
91.6
91.1
APRIL 2018

Advertisement

loading