GE VersaPoint IC220PBI002 User Manual page 192

Profibus-dp niu
Table of Contents

Advertisement

D
Module="IC220BEM232*SER COMM RS232 1CH"
0xC2,0xC0,0xC0,0xDC,0x01
60
Ext_Module_Prm_Data_Len = 25
Ext_User_Prm_Data_Const(0) =
0x02,0xd7,0x5f,0xff,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x
00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x0
0,0x00,0x00
Ext_User_Prm_Data_Ref(5) = 87
Ext_User_Prm_Data_Ref(6) = 88
Ext_User_Prm_Data_Ref(7) = 89
Ext_User_Prm_Data_Ref(10) = 90
Ext_User_Prm_Data_Ref(11) = 91
Ext_User_Prm_Data_Ref(12) = 92
Ext_User_Prm_Data_Ref(13) = 93
Ext_User_Prm_Data_Ref(15) = 94
Ext_User_Prm_Data_Ref(16) = 95
Ext_User_Prm_Data_Ref(17) = 96
Ext_User_Prm_Data_Ref(18) = 97
EndModule
Module="IC220BEM485*SER COMM RS485 1CH"
0xC2,0xC0,0xC0,0xDC,0x01
61
Ext_Module_Prm_Data_Len = 25
Ext_User_Prm_Data_Const(0) =
0x02,0xd7,0x5f,0xff,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x
00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x0
0,0x00,0x00
Ext_User_Prm_Data_Ref(5) = 87
Ext_User_Prm_Data_Ref(6) = 88
Ext_User_Prm_Data_Ref(7) = 89
Ext_User_Prm_Data_Ref(10) = 90
Ext_User_Prm_Data_Ref(11) = 91
Ext_User_Prm_Data_Ref(12) = 92
Ext_User_Prm_Data_Ref(13) = 93
Ext_User_Prm_Data_Ref(14) = 98
Ext_User_Prm_Data_Ref(16) = 95
Ext_User_Prm_Data_Ref(17) = 96
Ext_User_Prm_Data_Ref(18) = 97
EndModule
;********* power- and segment terminals ********
Module="IC220PWR003*PWR TERM F-D 24VDC"
0x42,0x00,0xBE,0xC2
62
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Const(0) = 0x00
EndModule
D-18
VersaPoint™ I/O System Profibus-DP NIU User's Manual August 2005
Module="IC220PWR013*SEG TERM F-D 24VDC"
0x42,0x00,0xBE,0xC2
63
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Const(0) = 0x00
EndModule
Module="IC220PWR014*SEG TERM ELF 24VDC"
0x42,0x00,0xBE,0xC2
64
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Const(0) = 0x00
EndModule
;************** ******************************
;********* device diagnostics ******************
;*********************************************
;*********************************************
;********* PROFIBUS standard diagnostics *****
; Byte 0 station state 1
; Byte 1 station state 2
; Byte 2 station state 3
; Byte 3 PROFIBUS master address
; Byte 4 00H (manufacturers ID high Byte)
; Byte 5 F0H (manufacturers ID low Byte)
;*********************************************
;********************************************
;*** device specific diagnostics (Status PDU format) *
;*********************************************
; Byte 6 09H (Header Byte, number of following byte)
; Byte 7 81H (type of diagnostics - Status PDU)
; Byte 8 first faulted device (INTERBUS Inline Slot Number)
; Byte 9 Specifier (appeared / disppeared / no change)
; Byte 10 error type
; Byte 11 error number
; meaning of error type-error number:
; 1: parameterization error PROFIBUS
; 1-1: wrong slot number
; 1-2: parameter block (failsafe or configuration) is incomplete
; 1-3: data length of a parameter block is too small
; 1-4: data length of a parameter block is too large
; 1-5: internal block length (failsafe and configuration) is too
small
; 1-6: header byte of parameterblock is incorrect
; 1-7: PCP-initialization for a module without PCP
functionality
; 1-8: too many data blocks for the module
; 2: configuration error PROFIBUS
GFK-1911B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Versapoint ic220pb001Versapoint ic220pbo002

Table of Contents