APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 22 of 38)
ADDR
REGISTER NAME
IEC 61850 XSWI configuration (read/write settings)
AECF
Operand for IEC 61850 XSWI1.ST.Loc status
AED0
Command to clear XSWI1 OpCnt (operation counter)
AED1
Repeated for IEC 61850 XSWI2
AED3
Repeated for IEC 61850 XSWI3
AED5
Repeated for IEC 61850 XSWI4
AED7
Repeated for IEC 61850 XSWI5
AED9
Repeated for IEC 61850 XSWI6
AEDB
Repeated for IEC 61850 XSWI7
AEDD
Repeated for IEC 61850 XSWI8
AEDF
Repeated for IEC 61850 XSWI9
AEE1
Repeated for IEC 61850 XSWI10
AEE3
Repeated for IEC 61850 XSWI11
AEE5
Repeated for IEC 61850 XSWI12
AEE7
Repeated for IEC 61850 XSWI13
AEE9
Repeated for IEC 61850 XSWI14
AEEB
Repeated for IEC 61850 XSWI15
AEED
Repeated for IEC 61850 XSWI16
AEEF
Repeated for IEC 61850 XSWI17
AEF1
Repeated for IEC 61850 XSWI18
AEF3
Repeated for IEC 61850 XSWI19
AEF5
Repeated for IEC 61850 XSWI20
AEF7
Repeated for IEC 61850 XSWI21
AEF9
Repeated for IEC 61850 XSWI22
AEFB
Repeated for IEC 61850 XSWI23
AEFD
Repeated for IEC 61850 XSWI24
IEC 61850 GGIO4 general analog configuration settings (read/write)
AF00
Number of analog points in GGIO4
IEC 61850 GGIO4 analog input points configuration settings (read/write)
AF10
IEC 61850 GGIO4 analog input 1 value
AF11
IEC 61850 GGIO4 analog input 1 deadband
AF13
IEC 61850 GGIO4 analog input 1 minimum
AF15
IEC 61850 GGIO4 analog input 1 maximum
AF17
...Repeated for IEC 61850 GGIO4 analog input 2
AF1E
...Repeated for IEC 61850 GGIO4 analog input 3
AF25
...Repeated for IEC 61850 GGIO4 analog input 4
AF2C
...Repeated for IEC 61850 GGIO4 analog input 5
AF33
...Repeated for IEC 61850 GGIO4 analog input 6
AF3A
...Repeated for IEC 61850 GGIO4 analog input 7
AF41
...Repeated for IEC 61850 GGIO4 analog input 8
AF48
...Repeated for IEC 61850 GGIO4 analog input 9
AF4F
...Repeated for IEC 61850 GGIO4 analog input 10
AF56
...Repeated for IEC 61850 GGIO4 analog input 11
AF5D
...Repeated for IEC 61850 GGIO4 analog input 12
AF64
...Repeated for IEC 61850 GGIO4 analog input 13
AF6B
...Repeated for IEC 61850 GGIO4 analog input 14
AF72
...Repeated for IEC 61850 GGIO4 analog input 15
AF79
...Repeated for IEC 61850 GGIO4 analog input 16
AF80
...Repeated for IEC 61850 GGIO4 analog input 17
AF87
...Repeated for IEC 61850 GGIO4 analog input 18
AF8E
...Repeated for IEC 61850 GGIO4 analog input 19
AF95
...Repeated for IEC 61850 GGIO4 analog input 20
AF9C
...Repeated for IEC 61850 GGIO4 analog input 21
GE Multilin
RANGE
UNITS
0 to 65535
0 to 1
4 to 32
---
0.001 to 100
–1000000000000 to
1000000000000
–1000000000000 to
1000000000000
C30 Controller System
B.4 MEMORY MAPPING
STEP
FORMAT
---
1
F300
---
1
F126
---
4
F001
---
---
F600
%
0.001
F003
---
0.001
F060
---
0.001
F060
DEFAULT
0
0 (No)
B
4
0
100000
0
1000000
B-29