Alarms, faults and system messages
6.1 Operating states indicated on LEDs
Table 6- 1
Table 6- 2
Table 6- 3
SAFE LED displays
Table 6- 4
134
Inverter diagnostics
LED
RDY
GREEN - on
GREEN - slow
RED - on
RED - slow
RED - fast
RED - fast
RED - fast
Communication diagnostics via RS485
LED BF
Explanation
OFF
Receive process data
RED - slow
Bus active - no process data
RED - fast
No bus activity
Communication diagnostics via PROFIBUS DP
LED BF
Explanation
off
Cyclic data exchange (or PROFIBUS not used, p2030 = 0)
RED - slow
Bus fault - configuration fault
RED - fast
Bus fault
- no data exchange
- baud rate search
- no connection
Diagnostics of the safety functions
SAFE LED
Meaning
YELLOW - on
One or more safety functions are enabled, but not active.
YELLOW - slow
One or more safety functions are active; no safety function faults have
occurred.
YELLOW - rapid
The inverter has detected a safety function fault and initiated a stop
response.
Explanation
BF
---
Ready for operation (no active fault)
---
Commissioning or reset to factory settings
OFF
Firmware update in progress
RED - slow
Firmware Update is complete, Power ON Reset
required
---
General fault
RED - on
Fault during firmware update
RED - fast
Incompatible firmware / incorrect memory card
Safety Integrated Function Manual, SINAMICS G120
Function Manual, 07/2010, FW 4.3.2, A5E03052391B AA