Rx VHF
Figure 38 shows the Rx VHF test points layout.
N7100 IC with
Integrated PLL
Lock voltage test point
DC voltage between
1V and 2 V
Page 42
Figure 38: Rx VHF test points
©2005 Nokia Corporation
Nokia Customer Care
RF test point:
367.2MHz @ -61 dBm
With Production probe
-1 dBm with HP Probe.