2255 (RM-97)
RF Description and Troubleshooting
The RF PDM Control dialog box appears.
Figure 8: RF PDM Control dialog box for Cell troubleshooting
13. Click Read Phone to update the values.
14. Configure the spectrum analyzer using the following values:
•
Center Frequency = 836.52 MHz
•
Span = 100 MHz
•
Amplitude = 20 dBm
•
Attenuation = Auto
•
BW = Auto
Adjust the following PDM field values on the RF PDM dialog box:
•
Set PA Gain State to High
•
Adjust Tx RF AGC PDM to around –250
•
Adjust Tx IF AGC PDM to around –250
•
Set Output level to +23dBm on CH-384 and monitor the current between
590mA and 660mA.
Failed Test: Tx PA Detector
1. Use Phoenix to set the phone in Local Mode, and activate the Tx with default
output power. The output power at the RF test connector should read
9 dBm +/- 4 dB.
2. Use a voltmeter on DC, and probe the detector output at C813. The voltmeter
should read approximately 1.4 V. If not, replace the detector (N803).
Page 10
©2005 Nokia Corporation
Nokia Customer Care
Company Confidential
ISSUE 1 10/2005