Advertisement

CONTENTS
Package Contents .................. 2
Product Registration ............... 2
Setup .................................... 5
Sensor Setup ......................... 5
Display Setup ........................ 6
Backlight Settings ................... 7
Questions?
877-221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Placement Guidelines ............. 8
Programmable Alarms. ..........10
Troubleshooting .................... 11
Care & Maintenance .............12
Calibration ...........................12
Specifications ........................13
FCC Information ...................13
Customer Support .................14
Warranty..............................14
Contact Customer Support at
Instruction Manual
Weather Station
model 02098

Advertisement

Table of Contents
loading

Summary of Contents for AcuRite 02098

  • Page 1: Table Of Contents

    Specifications ......13 Display Setup ......6 FCC Information ....13 Set the Time, Date & Units ..7 Customer Support ....14 Backlight Settings ....7 Warranty......14 Questions? Contact Customer Support at 877-221-1252 or visit www.AcuRite.com. SAVE THIS MANUAL FOR FUTURE REFERENCE.
  • Page 2: Unpacking Instructions

    Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference. Unpacking Instructions Remove the protective film that is applied to the LCD screen prior to using this product.
  • Page 3: Features & Benefits: Display

    Features & Benefits 10 7 FRONT OF DISPLAY 1. Current Outdoor Temperature Icon Arrow icon indicates the direction Indicates display is in auto-dimming temperature is trending. brightness mode (see page 7). 2. Outdoor Sensor Signal Strength 14. Current Indoor Humidity Arrow icon indicates direction humidity is 3.
  • Page 4 Features & Benefits BACK OF DISPLAY 1. Backlight Button 5. Plug-in for Power Adapter For momentary backlight and 6. Power Adapter dimmer settings. 7. Battery Compartment Cover 2. Integrated Hang Holes 8. RESET Button For easy wall mounting. For full reset to factory defaults. 3.
  • Page 5: Setup

    A-B-C switch setting inside the battery Install or Replace Batteries compartment. AcuRite recommends high quality 2. Insert 2 x AA batteries into alkaline or lithium batteries for the battery compartment, as the best product performance.
  • Page 6: Display Setup

    Display Setup Set the A-B-C Switch 2. Insert 3 x AAA alkaline batteries into the battery Locate the A-B-C switch inside compartment, as shown. Follow the battery compartment. Set the polarity (+/–) diagram in the A-B-C switch to A, B or C. the battery compartment.
  • Page 7: Set The Time, Date & Units

    Set the Time, Date & Units Press and release the “ ” button, located on the front of the display unit, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display. To adjust the currently selected (flashing) item, press and release the “...
  • Page 8: Placement Guidelines

    Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display and the outdoor sensor are critical to the accuracy and performance of this product. Display Placement Place the display in a dry area free of dirt and dust. Display stands upright for tabletop use or is wall-mountable.
  • Page 9: Using The Weather Station

    Weather Forecast AcuRite’s patented self-calibrating forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard. It generates a forecast with pinpoint accuracy - personalized for your exact location.
  • Page 10: Programmable Alarms

    Programmable Alarms This display features programmable alarms that sound an alert to notify you when a value (for time, temperature or humidity) has been reached or exceeded. When an alarm is triggered, the display emits an audible beep and flashes data in the affected category. You can customize the alarms by turning ON or OFF the alarms you’d like activated or deactivated, and by inputting your own values to trigger the alarm.
  • Page 11: Troubleshooting

    • Reset the display by pressing the reset button, located not working on the back of the display. Date and time will need to be entered after a reset. If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call 877-221-1252 for assistance.
  • Page 12: Care & Maintenance

    Care and Maintenance Display Care Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air. Outdoor Sensor Care Clean with a soft damp cloth. Do not use caustic cleaners or abrasives. Calibration The indoor/outdoor temperature and humidity readings, and barometric pressure can be calibrated on the display unit to improve accuracy.
  • Page 13: Specifications

    Specifications Outdoor: -40ºF to 158ºF; -40ºC to 70ºC TEMPERATURE RANGE Indoor: 32ºF to 122ºF; 0ºC to 50ºC Outdoor: 1% to 99% RH HUMIDITY RANGE Indoor: 1% to 99% RH 330 ft/100 m depending on home construction materials WIRELESS RANGE 433 MHz OPERATING FREQUENCY Display: 5V, 100mA power adapter POWER...
  • Page 14: Customer Support

    Customer Support AcuRite customer support is committed to providing you with best-in- class service. For assistance, please have the model number of this product available and contact us in any of the following ways: (877) 221-1252 AcuRite Visit us at www.
  • Page 16 Plan your day with confidence ™ www.AcuRite.com ©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy- rights are the property of their respective owners. AcuRite uses patented technology.