Raypak H7 504-2004 Specifications

Raypak H7 504-2004 Specifications

Mvb - type h heating/hot water supply boilers

Advertisement

Quick Links

Job:
Engineer:
Contractor:
Prepared By:
Model:
84% Thermal Efficiency at Full Rate
100% Factory Fire Tested
Maximum Outlet Water Temperature: 220°F
Minimum Acceptable Inlet Water Temperature: 120°F
Full Safety Diagnostics with History
Footprint: Less Than 5-1/2 ft
Limited Twenty-Year Thermal Shock Warranty
Limited Ten-Year Heat Exchanger Warranty
Electronic Modulation, Constant Ratio 1.4:1 Turndown
TempTracker Mod Controller with LCD Display
Status Display Lights
Heat Exchanger
Bronze Headers
ASME H Stamped
160 PSIG Working Pressure
National Board Approved
Fin Tubing
Copper – Standard
Cupro Nickel – Option A-3
ASME Powder-Coated Tube Sheet
Silicone High Temp O-Rings
ASME Pressure Relief Valve
60 PSIG – Standard
PSIG – Optional
Temperature and Pressure Gauge,
Shipped Loose
Stainless Steel Evaporator Plate
Control
120V, 60Hz, 1Ø, Power Supply
120/24V 60Hz Transformer
Ignition Module
3-Try – Standard
Single-Try – Option C-6
Hot Surface Ignition (HSI)
Remote Flame Sensor
High Limit, Manual Reset, Fixed,
240ºF
On/Off Power Switch
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switch
Pump Switch
Pump Time Delay
Diagnostics Panel
Modulating Temperature Control
Water Temperature Sensors (3)
Catalog No.: 2000.364A
Date:
Indoor/Outdoor:
2
Burner
Ultra-Low NOx: Less than 20 PPM
Gas Train
Fuel
Natural Gas
Propane
Zero Governor Regulator
Dual-Seat Combination Valve
Electronic Modulating Firing Mode
Construction
Indoor/Outdoor Construction
Front Controls Enclosed
PolyTuf Powder Coat Finish
Rear Connections (Water, Electrical,
Gas, Vent, Combustion Air)
Design Certified ANSI Z21.13/
CSA 4.9
Venting
Vent Termination Cap
Outdoor - Option D-11
Indoor, Horizontal – Option D-15
Indoor, Vertical (by others)
Combustion Air
In-Line Filter Kit – Option D-17
Air Intake Elbow – Option D-16
Extractor – Optional
By others
Not required
Effective: 8-15-07
MVB™ - Type H
Heating/Hot Water Supply Boilers
Temperature Controllers
B-36 Temp-Tracker Mod+ Digital
B-37 Temp-Tracker Mod+ Digital
B-38 Temp-Tracker Mod+ Digital
Y-241 Electronic Sequencer,
Y-281 Electronic Sequencer,
Options
A-13 Air Vent, Auto, 150 PSI
F-10 Low Water Cut-Off, Remote Probe
I-1
I-2
P-
P-
P-
S-1
S-2
Regulatory Agency Requirements
Replaces: 6-15-07
Models H7 504-2004
Controller, Up to 4 Boilers,
OA Reset
Controller, Up to 10 Boilers,
OA Reset
Controller, Up to 16 Boilers,
OA Reset
Up to 4 Boilers
Up to 8 Boilers
High Limit, Auto Reset, Adj.,
100-240°F
High Limit, Manual Reset, Adj.,
100-240°F
Pump:
HP, 120V, 1∅, 60Hz
Water Hardness:
GPG
Cast Iron
Bronze
Loose
Mounted
Cold Water Start
Cold Water Run
Low Gas Pressure Switch,
Manual Reset
High Gas Pressure Switch,
Manual Reset

Advertisement

loading

Summary of Contents for Raypak H7 504-2004

  • Page 1 Air Intake Elbow – Option D-16 Extractor – Optional By others Not required Replaces: 6-15-07 MVB™ - Type H Models H7 504-2004 Temperature Controllers B-36 Temp-Tracker Mod+ Digital Controller, Up to 4 Boilers, OA Reset B-37 Temp-Tracker Mod+ Digital Controller, Up to 10 Boilers,...
  • Page 2 * Closed systems only Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (800) 872-9725 www.raypak.com Raypak Canada Ltd. 2805 Slough St., Mississauga, Ontario, Canada L4T 1G2 (905) 677-7999 Fax (905) 677-8036 www.raypakcanada.com Catalog No.: 2000.364A Effective: 8-15-07 Dimensions (in.)

This manual is also suitable for:

H7-504H7-754H7-1104H7-1504H7-2004