Installing And Removing Hardware; Installing And Removing The Backup Battery - Siemens SIMATIC IPC427E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC427E:
Table of Contents

Advertisement

Device maintenance and repair

7.3 Installing and removing hardware

7.3
Installing and removing hardware
7.3.1

Installing and removing the backup battery

The service life of a backup battery is approximately 5 to 8 years, depending on the
operating conditions.
Note
An empty backup battery impairs the function of the device. Replace the backup battery in
good time.
Replace the backup battery only with a battery of the same type or a type recommended by
Siemens.
The article number of the backup battery is A5E34734290.
Dispose of used batteries in accordance with local regulations.
Requirement
● The device is disconnected from the power supply.
● No peripherals such as a mouse, keyboard or monitor are connected.
● 1 T10 screwdriver