Electrolux Premium Quick Reference Manual page 33

Thermoregulator management controller
Hide thumbs

Advertisement

ir33, ir33power and ir33DIN:
3
2
1
0
8
4
2
1
Fig. 7.q
Function
Disabled
set button
1
down/def button
2
up/aux button
4
prg/mute button
8
powercompact, powercompact small and MasterCella keypad
7
6
5
4
3
2
1
128
64
32
16
8
4
2
Fig. 7.r
Bit Mask
But-
Functions that can be enabled/disabled
ton
0
1
Enter HACCP;Report printing procedure
Set
1
2
Defrost;Continuous cycle;Enter HACCP
def
2
4
Enable/disable auxiliary output 1; Continuous cycle
aux
3
8
Mute
From ser. no.:
H2: Disable keypad and/or remote control
Parameter 'H2' can be used to inhibit some functions relating to the use of the keypad, for example, the modifi cation of the parameters
and the set point if the unit is accessible to the public.
The following options are available:
Parameter "H2"
HACCP
PRG/MUTE (mute)
UP/aux
DOWN/DEF (defrost)
set (modifi cation of type F parameters)
Modifi cation of the set point
Modifi cation from the remote control
ON/OFF
When the set point modifi cation and parameter modifi cation functions are inhibited, neither the set point nor the type F parame-
ters can be changed, while their values can still be displayed. The type C parameters, however, being password protected, can also
be modifi ed from the keypad, following the procedure described previously. With the remote control disabled, only the values of
the parameters can be displayed, but they cannot be modifi ed; in addition, the mute, defrost, continuous cycle, aux (auxiliary 1),
light (auxiliary 2) and on/off functions are disabled.
disabled. To re-enable the remote control, set H2=0 or H2=1 on the keypad.
Default: H2=1=> all enabled
H3: Enabling code for programming from the remote control
Parameter H3 assigns an access code to the remote control. As already described, this allows the remote control to be used when
there is more than one controller present on the same panel, without the risk of interference. For further details, see the paragraph
on the use of the remote control.
Default: H3=00 => programming from the remote control without code.
Tastiera standard
Tasto Set
H4: Disable buzzer
This parameter can have two values:
Tasto down/def
H4=0 buzzer enabled;
H4=1 buzzer disabled
Tasto up/aux
Default: H4=0=> buzzer enabled. Available on all models.
Tasto prg/mute
H6: Lock keypad
Using the corresponding bits, the functions relating to the individual buttons on the keypad can be enabled/disabled, according to
the following relationships:
Total (value of parameter H6): to calculate the value to be assigned to parameter H6, simply sum the values assigned to the
Value
+
functions that should be disabled.
For ir33, ir33power and ir33DIN see Table 7.q, for powercompact, powercompact small and mastercella see Table 7.q.
Important:
Example:
Tab. 7.p
Bit
0
1
0
1
2
Tastiera standard
Tasto Set
3
Tasto down/def
Tasto up/cc
4
Tasto prg/mute
5
Tasto haccp
Tasto aux
6
Tasto on/off
7
Tasto luce
Default: H6=0 => all buttons disabled.
H8: Select light or AUX output to activate with time band.
This parameter can be used to select the output that is activated or deactivate according to the time band (see parameters tON
and tOF).
H8=0=> Time band linked to output confi gured as the light.
H8=1=> Time band linked to output confi gured as AUX.
Note:
Default: H8=0 => Time band linked to the light.
H9: Enable set point variation with time band.
This parameter can be used to enable the variation of the set point according to the time band (see parameters ton and toF). The
controller modifi es the set point by adding the value of parameter r4 (to the time toF), the new value is used for all the functions
relating to the set point (e.g. relative high and low temperature alarms, control with dead band, control with two compressor
Tab. 7.q
steps etc.).
Page:33
Warnings:
the functions disabled using parameter H6 are added to those disabled using parameter H2.
disable the "SET button", "AUX button":
ir33, ir33power and ir33DIN: 1+4 = 5 = value or parameter H6;
powercompact, powercompact small and mastercella: 1+32 = 33 = value of parameter H6.
Value
Button
Functions that can be enabled/disabled
1
Report printing procedure
2
Defrost
4
Continuous cycle
8
Mute
16
Enter HACCP
32
Enable/disable auxiliary output 1
64
On/Off
128
Enable/disable auxiliary output 2
the output being controlled (light or AUX) must be available and selected with parameter H1.
Ed.1" 08-2014
0
1
2
3
4
If H2=2 or H2=3 is set on the remote control, this is immediately
560001 EG
Doc. No.:
5
6
Tab. 7.n
Tab. 7.o