Haltech HAL-HCO201 Operation Manual

Handheld carbon dioxide meter/monitor

Advertisement

Quick Links

HAL-HCO201
Handheld Carbon Dioxide
Meter/Monitor
Operational Manual
625 E Carroll Avenue
Glendora, CA 91741 USA
Phone: (510) 579-8540
Fax: (626) 236-9246
Info@haltechnologies.com
http://haltechnologies.com
Page 1 of 19

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HAL-HCO201 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Haltech HAL-HCO201

  • Page 1 HAL-HCO201 Handheld Carbon Dioxide Meter/Monitor Operational Manual 625 E Carroll Avenue Glendora, CA 91741 USA Phone: (510) 579-8540 Fax: (626) 236-9246 Info@haltechnologies.com http://haltechnologies.com Page 1 of 19...
  • Page 2 This Page intentionally left as blank Page 2 of 19...
  • Page 3: Table Of Contents

    Table of Contents Important Messages ................. 4 I. Introduction.................. 6 1.1 Features ................7 1.2 Specifications ................ 7 II. Basic Operation ................9 2.1 Measuring Screen ..............9 2.2 Browsing Screen ..............11 2.3 Setting Screen..............13 2.4 Calibration ................13 III.
  • Page 4: Important Messages

    Important Messages The information in this manual is believed to be accurate to date. However, Hal Technology assumes no responsibility for any inaccuracies that may be contained in this manual. In no event will Hal Technology be liable for direct, indirect, special, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages.
  • Page 5 It is strongly recommended that the instrument should be calibrated semi-annually or annually at most. Please contact Hal Technology to schedule your calibration or any services needed. The HAL-HCO201 can only be serviced at Hal Technology or by Hal Technology’s authorizing trained professionals.
  • Page 6: Introduction

    CO levels. With a built-in pump, the HCO201 is a point-to sample instrument and responds very quickly to ambient changes in CO concentration. The HAL-HCO201 Carbon Dioxide monitor can be widely used for continuous Page 6 of 19...
  • Page 7: Features

    environment monitoring system (CEMS), environment protection, hygiene and epidemic prevention system, as well as air pollution and greenhouse testing. 1.1 Features • Easy to use - minimal operator training required • Wide measuring range • Rapid response time • Direct real time readings allow immediate response to results •...
  • Page 8 • Calibration Interval: Typical not required • Display Unit: ppm (4 digit LCD) • Memory: Up to 500 sets of data • Interface: USB • Power: Rechargeable Lithium ion battery (3.7V/900mAh); AC adapter 100~ 240VAC to 5VDC/1A • Dimension: 80 (W) × 150 (H) × 36 (D) mm •...
  • Page 9: Basic Operation

    II. Basic Operation Six control keypads are used to operate the instrument: , RUN/STOP, ENTER, BACK, • Power button : Push and hold it for about 2 seconds to turn on the instrument. After turned on, keep pushing on for about 2 seconds to turn off the instrument. The instrument will shut off automatically to save the power after about 8 minutes standby or no operation, •...
  • Page 10 Measuring 2007-09-06 08:47:25 23°C 68%RH ---- mbar Figure 1 Measuring Screen Battery Indicator The battery indicator displays the battery strength graphically. Four bars represent 100% of charge in the battery; three bars 75%; two bars 50%; one bar 25%. No bars signify a low battery status and simultaneously the alarm will buzz as a warning.
  • Page 11: Browsing Screen

    • The instrument will automatically turn off the power in 8 minutes or so if no keypad action was received. However, the power will not be automatically turned off as long as a sampling (with a running pump) is in process. Pressure When it is applicable, the current pressure value will be displayed in Pa when an external pressure sensor is attached.
  • Page 12 • Use BACK keypad to return to the main Browsing window. BACK keypad is effective only after entering into the data record. Browsing 028/028 2008-08-06 08:42:25 Temp:24°C RH:56% Figure 3 An example of the Browsing Screen Record Record format as current number of saved data/total number of stored data. (e.g., 028/028).
  • Page 13: Setting Screen

    2.3 Setting Screen The Setting screen allows users to set or change Date, Time, and warning limit. Use an arrow and ENTER keypads to enter into the Setting screen. Then press the ENTER keypad to highlight the parameter that needs to be changed / set. The chosen parameter will be at the bottom of the window.
  • Page 14 Calibration 0000 0000 + 1000 1000 0610 + 0000 Reset Altitude: 0535 feet Figure 6 Calibration Screen - 1 Recommended calibration method is the standard Zero-Span technique. The X values in the first column represent the concentration of calibrating gas in ppm. The Y values in the second column represent the response of the sensor to be calibrated.
  • Page 15 5) Press RUN/STOP keypad to start a sampling. Wait for right bottom number stable and then press STOP key. 6) Connect the inlet to a glass container that is connected a standard CO gas cylinder (e.g., 1000ppm standard carbon dioxide gas cylinder). 7) Move the cursor to the second row (Refer to Figure 8) and then press the ENTER keypad.
  • Page 16: Warrantee

    III. Warrantee Hal Technology provides a one-year limited warranty of the Model HCO201 Handheld Carbon Monoxide meter, but not including necessary calibration service. • Warranty begins from shipping date. • The user is responsible for the cost of shipping in the case of any service or repair needed.
  • Page 17 including, but not limited to accident, misuse, unforeseeable use, neglect, alteration, improper installation, improper adjustment, improper repair, or improper testing, Hal Technology shall, at its option, repair or replace the equipment, shipment to Buyer prepaid. Hal Technology shall have reasonable time to make such repairs or to replace such equipment.
  • Page 18: Contact

    return shipping costs during the warranty period. Buyers may select a faster method of shipment at their own expense. Contact HAL TECHNOLOGY, LLC 625 E Carroll Avenue Glendora, CA 91741 USA Phone: (510) 579-8540 Fax: (626) 963-7302 Info@haltechnologies.com http://haltechnologies.com Information Record Model Serial No.
  • Page 19: User Registration Form

    Please fill out the Registration form below and send to: HAL TECHNOLOGY, LLC 625 E Carroll Avenue Glendora, CA 91741 USA Phone: (510) 579-8540 Or send relevant registration information to the email address below: services@haltechnologies.com User Registration Form Company _____ Contact Person ______________ Address...

Table of Contents