Siemens sitrans LR 400 Instruction Manual page 88

Hide thumbs Also See for sitrans LR 400:
Table of Contents

Advertisement

Chart 4
Display parameter
1. Line1 Local
2. Display Local
3. Level or
Volume Parameter
4. Line 2 Local
5. Level or
Volume Parameter
Supported HART Commands:
The SITRANS LR 400 conforms to HART rev. 5 and supports the following:
Universal Commands
0, 1, 2, 3, 6, 11, 12, 13, 14, 15, 16, 17, 18, 19
Common Practice Commands
33, 34, 35, 36, 37, 38, 40, 41, 42, 43, 44, 48, 50, 51, 53, 59, 108, 109, 110
Device Specific Commands
Command 128
Command 129
Command 130
Command 131
Command 132
Command 133
Command 134
Command 135
Command 136
Command 137
Command 138
Command 139
Command 140
Command 141
Command 142
Command 143
Command 144
Command 145
Command 146
Command 147
Command 148
Command 149
Command 150
Page 84
Line 1 Local
1. Level
2. Volume
Display Local
1. Eng unit
2. %
3. Bar graphic
Line 2 Local
1. Level
2. Volume
3. Temperature
4. Validity
5. S/N ratio
6. Amplitude
7. Digital output
8. Analog output
Read static data material
Write static data material
Read dynamic variables 1
Read dynamic variables 2
Read tank parameters
Write tank parameters
Read tank design
Write tank design
Read calibration array
Read calibration array
Read stilling pipe conditions
Write stilling pipe conditions
Read measuring conditions
Write measuring conditions
Read sensor set-up 1
Write sensor set-up 1
Read fix distance
Write fix distance
Read customer code
Write customer code
Read sensor set-up 2
Write sensor set-up 2
Read analog parameters
SITRANS LR 400 – INSTRUCTION MANUAL
7ML19985FH03