Specifications

Model Nr.: TH6320ZW2003
Model Name: T6 Pro Z-Wave Thermostat
Model Description: Programmable Z-Wave
thermostat with touchscreen
Stages:
Up to 3 Heat / 2 Cool Heat Pump
Up to 2 Heat / 2 Cool Conventional
Power requirements:
Battery power: AA alkaline battery 3pcs.
C-wire input: 18-30VAC; 50Hz-60Hz
Electrical Ratings:
Terminal
Voltage
(50/60Hz)
W Heating
18-30 Vac
(Powerpile)
750 mV DC
W2 (Aux) Heating
18-30 Vac
E Emergency Heat 18-30 Vac
Y Compressor
18-30 Vac
Stage 1
Y2 Compressor
18-30 Vac
Stage 2
G Fan
18-30 Vac
O/B Changeover
18-30 Vac
L/A Input
18-30 Vac
Dimension: 4.09" x 4.09" x 1.06"
Display size: 6.55 sq. in.
Temperature ranges:
Adjustable Heat Temperature Range Setting:
40-90 °F (4.5-32.0 °C)
Adjustable Cool Temperature Range Setting:
50-99 °F (10.0-37.0 °C)
Operating ambient temperature range:
37-102°F (2.78-38.89 °C)
Temperature Sensor Accuracy:
± 1.5 °F at 70 °F (0.85 °C at 21.0 °C)
Physical Dimensions in inches (mm) (H x W x D):
T6 PRO Z-Wave Thermostat (TH6320ZW2003):
4-5/64 x 4-5/64 x 1-1/16 (104 x 104 x 27)
UWP Mounting System (included):
2-9/32 x 2-13/64 x 2-43/64 (58 x 56 x 10)
Standard Installation Adapter (included):
3-29/32 x 3-57/64 x 21/32 (99 x 99 x 17)
Decorative Cover Plate – Small (included):
4-49/64 x 4-49/64 x 11/32 (121 x 121 x 9)
Decorative Cover Plate – Large (THP2400A1068):
6-7/64 x 6-7/64 x 9/32 (155 x 155 x 7)
Z-Wave Radio:
Frequency (USA and Canada): 908.42 MHz
Certified: Z-Wave Plus
Generic Device Type: Thermostat
Node type (C-wire): Always On Slave (AOS)
Node type (Battery): Listening Sleeping Slave (LSS)
Z-Wave Chipset: ZM5202AU
Supported Z-Wave Command Classes:
Z-
Wave Plus Info V2
Supervision V1
Transport Service V2
Association V2
Version V2
Association Group Information V2
Running
Basic V1
Current
Battery V1
0.02-1.0 A
Clock V1
100 mA DC
Configuration V4
Device Reset Local V1
0.02-1.0 A
Manufacturer Specific V2
0.02-0.5 A
Sensor Multilevel V5
0.02-1.0 A
Notification V3
Powerlevel V1
0.02-1.0 A
Security 2 V1
Thermostat Fan Mode V3
0.02-0.5 A
Thermostat Fan State V1
0.02-0.5 A
Thermostat Mode V3
0.02-0.5 A
Thermostat Operating State V1
Thermostat Setpoint V2
NOTES:
Thermostat Mode V3:
• Some of the reported modes are manufacturer
specific if not covered by the Z-Wave command
class.
Basic V1 (basic set command implementation):
• Value 0x00 Device goes to Energy saving setting
(AWAY mode)
• Values 0x01-0x63 and 0xFF Device goes to
Comfort setting (HOME mode)
Notification V3:
• Notification V3 is enabled by default (Power
management alarm handling). Notification
Type: Power Management (0x08). Notification
Events: AC mains disconnected (0x02), AC mains
re-connected (0x03).
Security:
• All supported Z-Wave Command classes are
supported securely (S2 unauthenticated), except
Transport Service V2, Security 2 V1 and Z-Wave
Plus Info V2
Association V2:
• Group ID: 1; Maximum Nodes: 1; Description:
Z-Wave Plus Lifeline
• Command Classes reported: Multilevel Sensor,
Thermostat Setpoint, Thermostat Mode
• Thermostat Fan Mode, Thermostat Operating
State, Thermostat Fan State, Basic