5

Technical Data

Board name
Order No.
Internal power supply voltage
External power supply voltage
Max. loading of encoder supply
Input current
Output driver current
Digital signals, limit frequency
Operating temperature
Storage temperature
Transport temperature
Environmental class for operation
-
Humidity:
-
Pollutant exposure:
Pollution level
Overvoltage category
Degree of protection
Mechanical stability
Dimensions
-
when stationary
-
during transport
Siemens AG
6SE7087-6CX84-3DB0
SIMOVERT MASTERDRIVES
3K3
3C2
2
II
IP00
[mm]
Width
160
Height
96
1)
Depth
46 / 56
Frequency range
Hz
10 to 60
above 60 to 500
5 to 9
above 9 to 500
1)
with 6SE7090-0XX84-3DB1
Digital tacho-Interface
DTI (digital tachometer interface)
6SE7090-0XX84-3DB0
15 V DC, 160 mA
24 V DC -16 % +25 %,
300 mA in the case of HTL encoder
24 V DC -16 % +25 %,
150 mA in the case of TTL encoder
HTL encoder: 300 mA
TTL encoder: 400 mA
HTL encoder: 12 mA
TTL encoder: 42 mA
HTL encoder: 15 mA
TTL encoder: 20 mA
f
400 kHz
max
0 °C to +55°C
-25 °C to +70°C
-25 °C to +70°C
acc. to DIN IEC 721 Part 3-3
DIN VDE 0110 Part 1
moisture condensation not permissible
DIN VDE 0110 Part 2
DIN VDE 0470 Part 1 = ^ EN 60529
DIN IEC 68-2-6
Constant amplitude of the
deflection
mm
0,35
3,5
Technical Data
acceleration
2
m/s
(g)
49 (5)
9,8 (1)
5-1