Example of Verifying VXLAN Flood and Learn Configuration
Example of Verifying VXLAN Flood and Learn Configuration
The following example shows the VXLAN Flood and Learn configuration verification.
VTEP-1:
VTEP-1# show nve vni
Codes: CP - Control Plane
Interface VNI
--------- -------- ----------------- ----- ---- ------------------ -----
nve1
nve1
VTEP-1# show running-config interface nve 1
interface nve1
no shutdown
source-interface loopback10
member vni 5000 mcast-group 209.165.1.1
member vni 7500 mcast-group 192.168.1.1
VTEP-1# show service instance vni detail
VSI: VSI-Ethernet7/17.1
If-index: 0x35310001
Admin Status: Up
Oper Status: Up
Auto-configuration Mode: No
encapsulation profile vni VSI_50_TO_5000
dot1q 50 vni 5000
Dot1q
------------------
50
VSI: VSI-Ethernet7/17.2
If-index: 0x35310002
Admin Status: Up
Oper Status: Up
Auto-configuration Mode: No
encapsulation profile vni TEST
dot1q 100 vni 7500
Dot1q
------------------
100
VTEP-1# show bridge-domain
Bridge-domain 50
Name:: Bridge-Domain50
Administrative State: UP
Bridge-domain 75
Name:: Bridge-Domain75
Administrative State: UP
VTEP-1# show mac address-table dynamic
Note: MAC table entries displayed are getting read from software.
Use the 'hardware-age' keyword to get information related to 'Age'
Legend:
Cisco Nexus 7000 Series NX-OS VXLAN Configuration Guide
32
UC - Unconfigured
Multicast-group
5000
209.165.1.1
7500
192.168.1.1
VNI
BD
5000
50
VNI
BD
7500
75
(2 ports in all)
VSI-Eth7/17.1
vni5000
nve1
(2 ports in all)
VSI-Eth7/17.2
vni7500
nve1
* - primary entry, G - Gateway MAC, (R) - Routed MAC, O - Overlay MAC
DP - Data Plane
SA - Suppress ARP
State Mode Type [BD/VRF]
Up
DP
L2 [50]
Up
DP
L2 [75]
Operational State: UP
Operational State: UP
Configuring VXLAN Flood and Learn
Flags