Backup Battery; Fuse - Honeywell Thor VM1 Reference Manual

Vehicle-mounted computer, microsoft windows embedded ce 6 operating system
Hide thumbs Also See for Thor VM1:
Table of Contents

Advertisement

The UPS status LED and the Battery Control Panel can be used to monitor the state of the UPS battery.
The UPS battery can be
replaced by the
user.

Backup Battery

The Thor VM1 has a permanent Lithium battery installed to maintain time, date and CMOS setup information for a minimum of
90 days. The lithium battery is not user serviceable and should last five years with normal use before it requires replacement.
Note:
The backup battery should only be changed by authorized service personnel.

Fuse

The Thor VM1 uses a 10A time delay (slow blow), fuse that is externally accessible and user replaceable. The fuse is located
on the back of the Quick Mount Smart Dock.
Should it need replacement, replace with same size, rating and type of fuse – Littelfuse 03260 10 MXP or equivalent.
Fuse has voltage on it even when power is off. Always disconnect input power before changing the fuse.