2. Adjusting Method
1)
Select the "HVL-F56AM/5600HS(D)" from the pull down menu of the flash adjustment program, then click the
Note:
Click the
2)
When checking message window "You select HVL-F56AM/5600HS(D)" appears, click the
The adjustment menu will appear as shown in Fig. 5-3-3.
Note:
Click the
[Charge Voltage Adj.]
3)
Click the
4)
Start the charge of the flash.
Note:
When the flash is already on full charge, push the test-flash button to fire the flash.
[250V Adj.]
5)
Click the
6)
Change the current output of the DC power supply to "0.5 A" to slow down the charging speed.
[305V Adj.]
7)
Click the
[330V Adj.]
8)
Click the
9)
When the adjustment is completed, click the
[Exit]
10) Click the
[End]
11) Click the
12) Perform the "5-4. FULL-CHARGE VOLTAGE/STOP CHARGE VOLTAGE CHECK".
HVL-F56AM
[End]
button to terminate the flash adjustment program.
[Exit]
button to disconnect the USB connection of PC.
Fig. 5-3-3
button.
Fig. 5-3-4
button of the adjustment menu when the voltage indicated on the digital multimeter reaches "250 V".
button of the adjustment menu when the voltage indicated on the digital multimeter reaches "305 V".
button of the adjustment menu when the voltage indicated on the digital multimeter reaches "330 V".
[Exit]
button to terminate the adjustment menu.