XPS Unified
EDH0373En1023 — 01/18
Input parameters
SocketID
PositionerName
PhaseCorrectionFilterNumber
PhaseCorrectionFn
PhaseCorrectionFd
PhaseCorrectionGain
Output parameters
None.
Return (In addition to the results of "Input Tests Common to all XPS
Functions")
• 0:
No error.
• -8:
Wrong object type for this command.
• -17:
Parameter out of range or incorrect.
• -18:
Positioner Name doesn't exist or unknown command.
• -134:
Changing the loop status is allowed in DISABLE state only.
310
int
Socket identifier gets by the
"TCP_ConnectToServer" function.
char *
Positioner name.
int Number of the selected phase correction
filter.
double
Numerator frequency (Hertz) for phase
correction filter.
double
Denominator frequency (Hertz) for phase
correction filter.
double
Gain for phase correction filter.