CPU MODULE
Item
Internal relay [M]
Link relay [B]
Timer [T]
Retentive timer [ST]
Counter [C]
Data register [D]
Link register [W]
Annunciator [F]
Edge relay [V]
Link special relay [SB]
Link special register [SW]
Special relay [SM]
Special register [SD]
RUN/PAUSE contact
Timer function
Allowable instantaneous power failure
period
5VDC internal current consumption
H
External dimensions
W
D
Weight
Protection of degree
*3
: The value for the CPU module whose serial number (first four digits) is "1207" or earlier is 0.43A.
5VDC internal current consumption: 0.43A
Remark
Table4.1 Performance Specifications (Continue)
6144 points by default (M0-6143) (changeable)
2048 points by default (B0 to 7FF) (changeable)
512 points by default (T0 to 511) (changeable)
(Sharing of low- and high-speed timers)
The low- and high-speed timers are specified by the instructions.
The measurement unit of the low- and high-speed timers is set up by
(Low-speed timer: 1 to 1000ms, 1ms unit, 100ms by default)
(High-speed timer: 0.1 to 100ms, 0.1ms unit, 10ms by default)
0 point by default
(sharing of the low- and high-speed retentive timers) (changeable)
The low- and high-speed retentive timers are specified
by the instructions.
The measurement unit of the low- and high-speed retentive timers
is set up by parameters.
(Low-speed retentive timer: 1 to 1000ms, 1ms unit, 100ms by default)
(High-speed retentive timer: 0.1 to 100ms, 0.1ms unit, 10ms by default)
Normal counter: 512 points by default (C0 to 511) (changeable)
6144 points by default (D0 to 6143) (changeable)
2048 points by default (W0 to 7FF) (changeable)
1024 points by default (F0 to 1023) (changeable)
1024 points by default (V0 to 1023) (changeable)
1536 points (SB0 to 5FF)
1536 points (SW0 to 5FF)
5120 points (SM0 to 5119)
5120 points (SD0 to 5119)
One contact can be set up in X0 to 17FF for each of RUN. No PAUSE
Year, month, date, hour, minute, second and day-of-week
(leap year automatically identified)
Accuracy: -3.18 to +5.25s (TYP.+2.14s)/d at 0
Accuracy: -3.18 to +2.59s (TYP.+2.07s)/d at 25
Accuracy: -12.97 to +3.63s (TYP.-3.16s)/d at 55
Varies depending on the power supply module.
For the general specifications, refer to CHAPTER 3.
QS001CPU
parameters.
contact.
*3
0.58A
98mm
55.2mm
114mm
0.29kg
IP2X
4.1 Performance Specifications
1
Remarks
2
The number of points
can be changed within
the setting range.
(
QSCPU User's
Manual
3
(Function
Explanation,
Program
Fundamentals)
4
The number of device
points is fixed.
5
Setting by parameters.
----
6
----
----
----
----
----
----
----
7
8
4
- 2