Height of the feed dogs

Standard
• The feed dog teeth should be 0.9 - 1.1mm above the needle plate at the highest position.
Adjustment
1. Loosen the setscrew
on the vertical feed arm
.
2. Loosen the fixation screw of the eccentric nut
.
3. Turn the eccentric nut
to make adjustment.
4 Retighten the fixation screw of the eccentric nut
.
5. Retighten the setscrew
.