Pump operation and space heating
When the room thermostat for the floor heating loop (T1) and the fan
coil units (T2) are connected to the indoor unit, the pump (3) will
operate when there is a request for heating from T1 and/or T2. The
outdoor unit will start operating to achieve the target leaving water
temperature. The target leaving water temperature depends on which
room thermostat is requesting heating.
Set point
Field setting
Zone A
First
UI
Zone B
Second
[7-03]
Resulting water temperature
Result pump operation
When the room temperature of both zones is above the thermostat
set point, the outdoor unit and pump will stop operating.
NOTICE
Make sure to connect the thermostat wires to the
correct terminals (see
page
5).
Make sure to configure the field settings [7-02], [7-03]
and [7-04] correctly. Refer to
on page
29.
Make sure to configure the DIP switch SS2-3 on the
PCB of the EBHQ* switch box correctly. Refer to
"12.2. Room thermostat installation configuration" on
page
21.
NOTICE
The request signals for space heating can be
implemented in two different ways (installer choice).
-
Thermo ON/OFF signal from room thermostat
-
Status signal (active/not active) from the mixing
station
It is the installers responsibility to make sure no
unwanted situations can occur (e.g. too high water
temperatures towards floor heating loops, etc.)
Daikin does not offer any type of mixing station. Dual
set point control only provides the possibility to use
two set points.
When only zone A requests heating, zone B will be
fed with water at a temperature equal to the first set
point.
This can lead to unwanted heating of zone B.
When only zone B requests heating, the mixing
station will be fed with water at a temperature equal to
the second set point.
Depending on the control of the mixing station, the
floor heating loop can still receive water at a
temperature equal to set point of the mixing station.
Be aware that the actual water temperature through
the floor heating loops depends on the control and
setting of the mixing station.
Installation manual
12
Thermo status
ON
OFF
ON
OFF
OFF
ON
ON
OFF
UI
[7-03]
[7-03]
ON
ON
ON
OFF
"5. Overview of unit" on
"Dual set point control"
9.
I
,
NSPECTING
HANDLING AND UNPACKING
THE UNIT

9.1. Inspection

At delivery, the unit must be checked and any damage must be
reported immediately to the carrier's claims agent.

9.2. Handling

The unit is packed in a cardboard box.
When handling the unit, take into account the following:
Fragile, handle the unit with care
Keep the unit upright

9.3. Unpacking

WARNING
Tear apart and throw away plastic packaging bags so that
children will not play with them. Children playing with
plastic bags face danger of death by suffocation.
Make sure that all accessories as mentioned in
supplied with the indoor unit" on page 5

9.4. Installing the unit

When installing the indoor unit, please refer to
installation location" on page 6
Mounting the indoor unit
1
Remove the front plate of the unit.
2
Hold the back plate against the wall and mark the fixation points
(2 on the top and 2 on the bottom).
Make sure that the marks (2 by 2) are completely level and the
dimensions of the marks are corresponding to the figure below.
390 mm
3
Drill 4 holes and install 4 plugs (suitable for M5).
4
Put the screws in the top plugs and hang the indoor unit on the
screws.
5
Put the screws in the bottom plugs.
6
Fix the 4 screws firmly.
"4.2. Accessories
are available in the unit.
"6. Selecting an
to select an appropriate location.
EKCBX/H008BBV3