Operation; Power Up; Dc In; Dc Out - JVC CamiFlex FG-CAM-F4/U User Manual

Camera over fiber extender
Table of Contents

Advertisement

CamiFlex Base Unit – Head Unit

3 OPERATION

3.1 Power Up

Camera should be switch ON after Base Unit and OFF before. During the product power up, Tally and
Fibre LEDs are blinking in orange indicating the product is booting up. This can take a few seconds.
During the system boot, the fibre LED is lighted in yellow during 2 seconds then switch off if the fibre is
correctly connected. If the fibre LED blinks in red, this means there is a connection problem between
Base Unit and Head Unit.

3.2 DC IN

Head Unit can be powered in 2 ways:
a) Through a Hybrid Fibre: the power supply conveyed on the Hybrid Fibre (48V) is internally
converted by Head Unit for internal and external need (13.2V DC OUT - see next section).
Base Unit
100-240V~
Head unit can also be powered locally to give power redundancy
100-240V~
b) Through local power supply: Head Unit is powered by DC IN connector (From +8V to +24V IN).
In such case DC OUT is unused.
100-240V~

3.3 DC OUT

The Head Unit provide DC OUT in order to power the Camera + accessories. This output is active
only when using a Hybrid Fibre
The certified maximum output power is 40W under 13.2V at 200 meters.
Hybrid
Fiber
Base Unit
Hybrid
Fiber
Base Unit
Tactical
Fiber
-12-
Head Unit
DC OUT
13.2V 40W
Head Unit
DC IN
12V
Head Unit
DC IN
12V

Advertisement