Download Print this page

Siemens sinamics G130 Operating Instructions Manual page 16

Motor reactors
Hide thumbs Also See for sinamics G130:

Advertisement

Mechanical installation
Table 3- 1
6SL3000-
Connection
Lengths n1 and n2 correspond to the drill hole spacing
1)
Table 3- 2
6SL3000-
Connection
Lengths n1 and n2 correspond to the drill hole spacing
1)
16
Dimensions of motor reactor, 380 V – 480 V 3 AC, part 1 (all specifications in mm)
2BE32-1AA0
Type 1
type
a2
25
a3
5
a4
12.5
a5
11
I4
300
I5
100
h1
-
h2
194
h3
60
h4
285
n1
163
1)
n2
224
1)
n3
257
n4
79
n5
-
d3
M8
Dimensions of motor reactor, 380 V – 480 V 3 AC, part 2 (all specifications in mm)
2BE35-0AA0
Type 2
type
a2
30
a3
6
a4
15
a5
14
I4
300
I5
100
h1
-
h2
245
h3
60
h4
365
n1
183
1)
n2
224
1)
n3
277
n4
79
n5
-
d3
M10
2BE32-6AA0
2BE33-2AA0
Type 1
25
5
12.5
11
300
100
-
227
60
315
183
224
277
79
-
M8
2AE36-1AA0
2AE38-4AA0
Type 1
40
8
20
14
410
140
392
252
120
385
191
316
292
84.5
30
M10
Operating Instructions, 04/2014, A5E00409660A
2BE33-8AA0
Type 1
Type 1
25
25
5
5
12.5
12.5
11
11
300
300
100
100
-
194
194
60
60
285
285
163
183
224
224
257
277
79
79
-
M8
M8
2AE41-0AA0
Type 1
Type 1
40
40
8
8
20
20
14
14
410
410
140
140
392
392
252
252
120
120
385
385
191
206
316
316
292
302
84.5
79.5
30
M10
M10
Motor reactors
-
-
-