1.1.3 Photo of Rear Panel …..……………………………………..14 1.2 Hardware Specification …..…………………………………………… 15 1.3 System I/O ……………………………………………………………… 16 1.3.1 Spectra PowerBox 100-IoT……………………………….…… 16 1.3.2 Spectra PowerBox 100-IoT with modules..……………….…… 18 1.4 Mechanical Dimension …..……………………………………………. 19 Chapter 2 Jumpers and Connectors 2.1 Jumper Setting ………………………………………………………..21 2.2 Location of the Switches and Connectors……..……………………..
Page 3
4.7.1 Save Changes and Reset………………………………………. 64 4.7.2 Discard Changes and Reset……………………………………. 64 4.7.3 Restore Defaults …………………………………………………. 64 4.7.4 Save as User Defaults ……………………………………………64 4.7.5 Restore User Defaults ………………………..…………………. 64 Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT...
Page 4
8.2.2 Restarting the Node-Red Process .…...…..….…………….. 8.2.3 Stopping the Node-Red Process .…...…..….…………….. 8.2.4 Starting the Node-Red Process ……..……..….…………….. 8.3 Activities for Repairing Node-Red Instances Not Starting ……….. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT...
(such as a fuse, battery, etc.), are not warranted. Before sending your product in, you will need to fill in a Spectra RMA Request Form and obtain a RMA number from us. Please go to www.spectra.de/RMA...
This indication alerts operators to an operation that, if not strictly observed, may result in safety hazards to personnel or damage to equipment. This indication provides additional information to complete a task easily. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
The equipment has obvious signs of breakage. 14. CAUTION: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Before installation, please ensure all the items listed in the following table are included in the package. Item Description Q’ty Spectra PowerBox 100-IoT Embedded System Spectra Linux OS Recovery stick * Power Terminal Block Connector (Male) Screw Pack (for HDD / Mini-PCIe / Wall & VESA Mounting) Wall Mount Kit DVI-I to VGA Adapter Remote Power On/Off Terminal Block Connector (Male) Note: Notify your sales representative if any of the above items are missing or damaged.
J1900 (2.0GHz) platform; it has integrated HD graphics processor. This can bring economic advantages on budget and also fulfill the needs for industrial computing tasks. The Spectra PowerBox 100 manages to pack a diverse array of I/O into its small form factor, with one DVI-I port, two RS-232/422/485 COM ports, dual Gb LAN ports, four USB ports and one set of Mic-in and Line-out.
• FCC Class A • 1x Remote Power On/Off Connector (2-pin Terminal Block) Operating System • 1x Universal I/O Bracket • Spectra Linux OS, 64-bit • 2x Antenna Holes Power Requirement • Support AT/ATX Power Mode • Power Input Voltage 9~48VDC •...
Used to connect a microphone Remote Power Terminal Block Line-out Used to plug a remote power on/off switch with Used to connect a speaker terminal block Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Page 17
COM / DisplayPort / DVI / VGA. Do not change the module by yourself, it may cause damage to your Spectra PowerBox 100. Please contact with your regional dealer for more information about it. Spectra GmbH & Co. KG User Manual Version 1.1...
Chapter 1: Product Introductions 1.3.2 Spectra PowerBox 100 Series w/ modules w/ PB-100-COM Front Rear w/ PB-100-DP w/ PB-100-DVI Front Rear w/ PB-100-VGA Front Rear Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Chapter 1: Product Introductions 1.4 Mechanical Dimensions Each of the Spectra PowerBox computers has the same mechanical dimension Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Chapter 2: Jumpers and Connectors 2.1 Jumpers Settings The Spectra PowerBox 100 is featured with jumper-free design 2.2 Location of the Jumpers and Connectors 2.2.1 Top View Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT...
Chapter 2: Jumpers and Connectors 2.2.2 Bottom View Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
MINIPCIE1 Mini PCI-Express Socket PWR_SW2 External Power Connector SATA1 SATA with Power Connector USB2_1 / USB2_2 / USB2_3 USB 2.0 Connector USB3_1 USB 3.0 Connector Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Switch Definition Right ATX Power Mode(Default) Left AT Power Mode CLR_CMOS1:Clear CMOS Switch Switch Definition Clear CMOS Normal Status (Default) PWR_SW1:Power Switch Definition Power Button Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
2.5.4 PWR_SW2:External remote power on/off switch (Note: Please do not apply power to the pins. This port is used to apply a switch.) 1 2 Definition PWR_ON Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
RX2- GND2 DSR2 RTS2 CTS2 NOTE: (For Spectra PowerBox w/ PB-100-COM Modul only) The optional module 2 COM ports <RS232 / RS422 / RS485> are with +5/ +12VDC for RI pin (Pin 9). Spectra GmbH & Co. KG User Manual Version 1.1...
10Mbps Network Link 2.5.11 LED1:Power / HDD Access LED Status Definition HDD LED+ HDD LED- POWER LED+ POWER LED- LED Status LED Color Yellow POWER Green Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Chapter 3: System Setup 3.1 Wall Mount Brackets The Spectra PowerBox 100 offers Wall Mount that customers can install system on the wall in convenient and economical way. 1. The mounting holes are at the bottom of system. Use provided 4 screws to fasten the bracket with each side of system together.
Chapter 3: System Setup 3.2 Side Mount Bracket The Spectra PowerBox 100 offers Side Mount that customer can install system to the right or left side of wall to create effective of space. 1. The mounting holes are at the bottom of system. Fasten the 4 screws to fix the side mount bracket with system together.
Chapter 3: System Setup 3.3 VESA Mount Brackets The Spectra PowerBox 100 offers VESA Mount that customer can mount system with panel complying with VESA 75mm and 100 mm standard for various usage. 2. Provided below is mounted with VESA 1.
Chapter 3: System Setup 3.4 DIN-Rail Mount Bracket The Spectra PowerBox 100 offers DIN-Rail Mount that customer can install system on the DIN Rail. 1. The mounting holes are at the bottom of system. Fasten the 2 screws to fix the DIN- Rail mount bracket with system together.
Then you can use the control keys to enter values and move from field to field within a sub-menu. If you want to return to the main menu, just press the <Esc>. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
4.2.1 System Date Set the date. Please use <Tab> to switch between date elements. 4.2.2 System Time Set the time. Please use <Tab> to switch between time elements. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT...
You can select any of the items in the left frame of the screen to go to the sub menus. 4.3.1 ACPI Settings ■ Enable ACPI Auto Configuration This enables ACPI power management of the system. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
■ Serial Port 4 Configuration This allows you to configure serial port 4. We’ll use serial port 1 configuration as an example in the manual. Similar settings apply to other serial ports configuration. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Page 43
Entering serial port 1 configuration allows you to enable or disable the port ,and also to configure settings and mode of operations. To avoid conflicted setting with other serial ports, default setting is recommended. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Page 44
Chapter 4: BIOS Setup Entering parallel port configuration allows you to enable or disable the port ,and also to configure settings and mode of device operation. Default setting is recommended. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Chapter 4: BIOS Setup 4.3.3 Hardware Monitor This allows you to monitor system’s CPU temperature and voltages. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Chapter 4: BIOS Setup 4.3.4 Serial Port Console Redirection This allows you to enable and disable serial (COM) port(s) for console use. Default setting is disabled. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Use of default setting is recommended in the section. ■ Limit CPUID Maximum Default is Disabled. ■ Execute Disable Bit Default is Enabled. ■ Intel Virtualization Technology Default is Enabled. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Page 48
Chapter 4: BIOS Setup Entering Socket 0 CPU Information shows CPU hardware details and supported features. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
This allows you to configure temperature of ACPI of OS to trip or shut down the system, or to begin throttling CPU. Use of default setting is recommended in the section. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Page 50
This allows 90C (default), 87C, 85C, 79C, &1C, 63C, 55C, 47C, 39C, 31C, 23C, 15C. ■ Passive Trip Point This allows 90C, 87C, 85C (default), 79C, &1C, 63C, 55C, 47C, 39C, 31C, 23C, 15C. ■ DTS Default is Disabled. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT...
■ SATA Mode This allows to set AHCI mode (default) or IDE mode. ■ Serial-ATA Port 0 Default is Enabled. ■ Serial-ATA Port 1 Default is Enabled. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Chapter 4: BIOS Setup 4.3.8 OS Selection For the Spectra Linux OS to operate properly, this option has to be ste to “all other OS”. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Chapter 4: BIOS Setup 4.3.9 CSM (Compatibility Support Module) Configuration Following shows default settings. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Page 54
Allows user to select whether to enable the UEFI or legacy option ROM for the storage device controller. Do not launch: Disables option ROM. UEFI: Enables UEFI option ROM only. Legacy: Enables legacy option ROM only. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT...
Chapter 4: BIOS Setup 4.3.10 USB Configuration Following shows default settings. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
Page 56
Determines whether to enable EHCI Hand-off feature for an operating system without EHCI Hand-off support. ■ USB Mass Storage Driver Support Enables or disables support for USB storage devices. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT...
You can select any of the items in the left frame of the screen to go to the sub menus. 4.4.1 North Bridge This section provides information on the installed memory size and memory/onboard graphics-related configuration options. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT...
Page 58
This item will allow users to enable or disable DOP CG. GTT Size GTT size optimal between 1MB or 2MB. IGD Thermal This item will allow users to enable or disable IGD Thermal. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT...
Chapter 4: BIOS Setup 4.4.2 South Bridge Following shows default settings. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT November 2017...
USB Port 2 This item will allow users to enable or disable USB Port 2. USB Port 3 This item will allow users to enable or disable USB Port 3. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Page 61
PCI Express Port 3 This item will allow users to enable or disable PCI Express Port 3. Speed Change the PCI Express interface speed. Select <AUTO> ,<Gen 2> or <Gen 1> Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
4.5.1 Administrator Password Administrator Password controls access to the BIOS Setup utility. 4.5.2 User Password User Password controls access to the system at boot and to the BIOS Setup utility. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
4.6.4 Fast Boot This item allows user to enable or disable Fast Boot option. 4.6.5 UEFI Boot This allows to boot device with UEFI-based (not legacy) OS. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de Spectra PowerBox 100-IoT...
This item allows user to save the changes done so far as user defaults. 4.7.5 Restore User Defaults This item allows user to restore the user defaults to all the options. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
5.1 PB100 IoT Mouse / Keyboard Commissioning The Spectra PowerBox 100-IoT is switched on by pressing the power button at the front of the housing. Input devices such as mouse and keyboard are connected via the USB ports which are also located at the front side.
During our regular office hours (Monday to Friday from 8 am to 5 pm), the Spectra support will generate a reset key which must be entered in the field “Please enter your reset key below”.
To prevent unauthorised persons from accessing the Web interface, the password of the Web interface user should be changed immediately after having commissioned the Spectra PowerBox 100-IoT! 5.2.4 Changing the Password of the Web Interface User Click on the avatar ( ) in the top right section to access your password change.
5.3.2 Changing the Computer Name of the Spectra PowerBox 100-IoT At the HOSTNAME menu item, the computer name of the Spectra PowerBox 100-IoT can be changed. To ensure that all services are correctly functioning, the Spectra PowerBox 100-IoT must be restarted after having successfully changed the computer name! 5.3.3 Creating User Accounts for Node-Red / Allowing Anonymous Use...
At the “NETWORK CONFIGURATION” menu item, the network can be configurated. The Web interface only allows for the configuration of the Ethernet network interfaces integrated in the Spectra PowerBox 100-IoT. Any optionally available WiFi hardware is configured via the XFCE operating system interface.
Page 71
5.3.4.1 General Settings The “Offline Mode” option enables the user to switch off the complete network system of the Spectra PowerBox 100-IoT (including optionally available WiFi components) and to set it to “Flight Mode”. If you only want to disable the integrated Ethernet network interfaces, you just have to remove the checkmark from the “Wired Networking enabled”...
Page 72
5.3.4.2 Wired Connections Here, the Ethernet interfaces of the Spectra PowerBox 100-IoT can be configured. The colour indicator next to each interface designation shows whether an active network cable is applied to the interface or not. In the as delivered state, both ETH interfaces are configured so that the IPv4 address is automatically obtained via DHCP.
Page 73
The currently obtained IP address is indicated in the corresponding fields. To reload the screen, you must possibly access the “Network Configuration” menu item again and click on the “Wired Connections” tab. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Page 74
The Web interface checks the entered addresses for plausibility. However, the topology of the network landscape must always be assessed by an administrator and/or system integrator which is familiar with the network. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Desktop settings and profile of the user “pbgui” The screen allows for • starting a backup run • accessing a list of earlier backups saved on the Spectra PowerBox 100-IoT • downloading backups • deleting backups Spectra GmbH & Co. KG User Manual Version 1.1...
Backups, however, will be maintained. MQTT-Broker Configuration The Spectra PowerBox 100-IoT is equipped with an MQTT-Broker which can be used to deliver messages on the basis of the MQTT protocol. Configuration changes must be saved by clicking on the “Save changes” button. The changes are applied by clicking on the “Apply changes”...
MQTT user account opens up. Here, you must enter the desired user name and a password. The specified login data must now be entered in the corresponding MQTT configurations (devices and/or Node-Red)! Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Spectra PowerBox 100-IoT. When enabling the SSL/TLS encryption for the first time by checking the “Use SSL/TLS encryption” box, the following dialogue opens up which, however, does not yet include any certificates. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Page 80
Click on the “Create new Root-CA” button to generate your own certification authority on the Spectra PowerBox 100-IoT. The setting process may take some time. Note: Each click on this button creates new certificates which in turn requires the reconfiguration of the services and devices connected to the broker! The “SSL Listener Port”...
The subject matter of individual license conditions is that the source codes must also be made accessible. On a case-by-case basis, Spectra GmbH & Co. KG refers to the publicly available source code archives of each software project (Github, Sourceforge, etc.). Some of the binary software components are the intellectual property of Spectra GmbH &...
6.1 General The operating system of the Spectra PowerBox 100-IoT has a graphic user interface which allows for the easy use of the system without extensive Linux knowledge and on the basis of the user-friendliness which you know from the standard operating systems in your office environment.
6.3.1 Screen Resolution The screen resolution can be set as follows: Start the “Settings Manager” via the Start button -> Settings. Now you can make the desired settings in the “Display” item. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Now left-click on the desired wireless network in the left column and press the “Connect” button. Here you can also define whether the IP address is to be assigned statically or configured by the DHCP server. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
In the as delivered state, there are shortcut icons on the desktop. • Trash: File recycle bin • File system: Access to the file system of the Spectra PowerBox 100-IoT (file manager) • Home: The “User directory” of the user account “pbgui” •...
7.1 General As already mentioned, no specific Linux knowledge is required for using the Spectra PowerBox 100-IoT. However, in rare cases, the Linux console must be used for some functions and maintenance options. Moreover, it might become necessary to inspect protocols, in particular when developing Node-Red flows.
7.3.1 Acquiring Administrator / Root Rights Since the operating system of the Spectra PowerBox 100-IoT includes the “sudo” package, you have the choice between three approaches to run commands with the root rights. Any command requiring root rights can be prefixed with ”sudo”. Example: „sudo /etc/init.d/pm2-init.sh restart“...
Web interface and offer Node-Red updates. Since the application situation of the Spectra PowerBox 100-IoT as well as the update strategy of the user may be very different, these updates must be installed explicitly. Relating to Node-Red, please note that there might be compatibility issues with existing flows between the different versions and that they should be adjusted at first.
Page 91
If individual services do not work as expected after the update, you should reboot the Spectra PowerBox 100-IoT. As described above, the operating status of the relevant services can be viewed via the start page of the Web interface.
Node-Red editor, the process logics must be individually programmed in most of the cases due to the diversity of data structures. The user manual of the Spectra PowerBox 100-IoT can only cover the technical operation of Node-Red, also for reasons of topicality. Since Node-Red is continuously developing, the online documentation should be the first source for details on Node-Red nodes and flow programming.
The Node-Red process can be stopped by running the command pm2 stop node-red. 8.2.4 Starting the Node-Red Process The Node-Red process can be started by running the command pm2 start node-red. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...
Optionally, you may try to remove the error from the flow file and then restart the process. In general, it is also possible to import a backup via the Web interface thus restoring functional operation. Spectra GmbH & Co. KG User Manual Version 1.1 vertrieb@spectra.de...