APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 32 of 42)
ADDR
REGISTER NAME
C378
...Repeated for Virtual Output 74
C380
...Repeated for Virtual Output 75
C388
...Repeated for Virtual Output 76
C390
...Repeated for Virtual Output 77
C398
...Repeated for Virtual Output 78
C3A0
...Repeated for Virtual Output 79
C3A8
...Repeated for Virtual Output 80
C3B0
...Repeated for Virtual Output 81
C3B8
...Repeated for Virtual Output 82
C3C0
...Repeated for Virtual Output 83
C3C8
...Repeated for Virtual Output 84
C3D0
...Repeated for Virtual Output 85
C3D8
...Repeated for Virtual Output 86
C3E0
...Repeated for Virtual Output 87
C3E8
...Repeated for Virtual Output 88
C3F0
...Repeated for Virtual Output 89
C3F8
...Repeated for Virtual Output 90
C400
...Repeated for Virtual Output 91
C408
...Repeated for Virtual Output 92
C410
...Repeated for Virtual Output 93
C418
...Repeated for Virtual Output 94
C420
...Repeated for Virtual Output 95
C428
...Repeated for Virtual Output 96
Mandatory (Read/Write Setting)
C430
Test Mode Function
C431
Force VFD and LED
C432
Test Mode Forcing
Clear commands (read/write)
C433
Clear All Relay Records Command
Contact Outputs (Read/Write Setting) (64 modules)
C440
Contact Output 1 Name
C446
Contact Output 1 Operation
C447
Contact Output 1 Seal In
C448
Latching Output 1 Reset
C449
Contact Output 1 Events
C44A
Latching Output 1 Type
C44B
Reserved
C44C
...Repeated for Contact Output 2
C458
...Repeated for Contact Output 3
C464
...Repeated for Contact Output 4
C470
...Repeated for Contact Output 5
C47C
...Repeated for Contact Output 6
C488
...Repeated for Contact Output 7
C494
...Repeated for Contact Output 8
C4A0
...Repeated for Contact Output 9
C4AC
...Repeated for Contact Output 10
C4B8
...Repeated for Contact Output 11
C4C4
...Repeated for Contact Output 12
C4D0
...Repeated for Contact Output 13
C4DC
...Repeated for Contact Output 14
C4E8
...Repeated for Contact Output 15
C4F4
...Repeated for Contact Output 16
C500
...Repeated for Contact Output 17
C50C
...Repeated for Contact Output 18
GE Multilin
RANGE
0 to 1
0 to 1
0 to 65535
0 to 1
---
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 1
---
B90 Low Impedance Bus Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F245
---
1
F126
---
1
F300
---
1
F126
---
---
F205
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F090
0 (Operate-dominant)
---
---
F001
DEFAULT
B
0 (Disabled)
0 (No)
1
0 (No)
"Cont Op 1"
0
0
0
1 (Enabled)
0
B-39