Baumer CombiLyz AFI5 Manual

Inductive conductivity transmitter
Hide thumbs Also See for CombiLyz AFI5:

Advertisement

Quick Links

TYPE EL - CLASS I
DECEMBER 2012

Technical specifications

Housing material
Cable (AFI5)
Material
Temperature
Process connection
Insertion length
Standard
Medium
Long
Material
Not wetted
Wetted parts
Surface
Wetted parts
Measuring range
Conductivity
Concentration
Temperature
Accuracy
Cond./conc.
(sensor incl. transmitter
@ 25°C ambient)
Temperature
Temperature compensation
Compensation range
Reference temperature
Sampling time
Response time
Cond./conc.
Temperature
Start up time without display
Start up time with display
www.baumer.com
FlexHousing, Ø80 mm
Stainless steel, AISI 304
2.5 / 5.0 / 10.0 meter
PUR
-40...80°C
G1B hygienic, rotating
(for other connections see adap-
ters page 4)
37 mm / hygienic version 41 mm
60 mm / hygienic version 64 mm
83 mm / hygienic version 87 mm
Stainless steel AISI 304
PEEK natura, unfilled
Ra < 0.8 µm
0 ... 500 µS/cm ... 0 ... 1000 mS/cm
14 selectable ranges
4 factory set media/ranges
1 customer defined media/range
-30 ... 150°C
Free programmable range
0 ... 500 µS/cm
≤ 1.5 %
0 ... 1 / 0 ... 500 mS/cm ≤ 1.0 %
0 ... 1000 mS/cm
≤ 1.5 %
≤ 0.4°C
0.0 ... 5.0% / K, free adjustable
-20 ... 150°C
25°C (adjustable)
< 0.3 second
t
< 2.0 seconds
90
t
< 15 seconds
90
≤ 10 seconds
≤ 15 seconds
CombiLyz AFI4 / AFI5
Inductive conductivity transmitter

Main features

Range from 500 µS/cm to
1000 mS/cm
All hygienic design
„„
Built in graphical display
„„
CombiView DFON
Very fast temperature compen-
sation
Easy and full programmable
with FlexProgrammer 9701
AFI5 split version with remote

Applications

Controlling CIP procedure
Controlling filling machines
Detection of specific medias
Water systems with >50 µS/cm
Electrical specifications
Power supply
Output
Cond./conc.
Temperature
Relays
(for more information
please see page 3)
Temperature drift Conductivity
Temperature
El. connection
Left side
Right side
Material
General specifications
Media temperature
Media pressure
Ambient
Without display
temperature
With display
Isolation voltage
Protection
EN60529/A2:2013 IP67 / IP69K
class
Humidity
IEC 68.2.38
Vibrations
1)
Factor of change in process temperature from 25°C
2)
Range 0...500 µS/cm ≤0.3%/K
Data sheet AFI4 / AFI5
sensor
Separate 4...20 mA output
for conductivity / concentra-
tion and 4...20 mA output for
temperature
FDT software
3-A approved
EHEDG
Touch screen
15 ... 35 VDC
4 ... 20 mA
4 ... 20 mA + HART
®
4 ... 20 mA
2 relays included in the display
Without display
With DFON display, 2 relay-output
galvanic separated
≤ 0.1%/K
1) 2)
≤ 0.5%/K
1)
AFI5: ≤ 0.5%/K + 0.005%/K pr. m
sensor cable
M12, 4-pin
M16 or M20 cable gland
M12, 4-pin (4 ... 20 mA output only)
M12, 8-pin (4 ... 20 mA + relay output)
M16 or M20 cable gland
Plastic (PA)
Stainless steel
-20 ... 140°C
150°C up to 1 hour
< 25 bar (helium tested)
-40 ... 85°C
-30 ... 80°C
500 VAC
98% condensing
IEC 60068.2.6 - test Fc
1.0 mm (2-13.2 hz) 0.7g (13.2-100 hz)
Page 1 / 7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CombiLyz AFI5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Baumer CombiLyz AFI5

  • Page 1 1.0 mm (2-13.2 hz) 0.7g (13.2-100 hz) Start up time without display ≤ 10 seconds Start up time with display ≤ 15 seconds Factor of change in process temperature from 25°C Range 0...500 µS/cm ≤0.3%/K Data sheet AFI4 / AFI5 Page 1 / 7 www.baumer.com...
  • Page 2 Optimal readability -10 ... 70°C Measuring unit μS/cm, mS/cm Operating -30 ... 80°C °C, °F temperature 8 × 20 pixel matrix User defined unit Mechanical data Material Polycarbonate Protection class IP67/IP69K www.baumer.com Data sheet AFI4 / AFI5 Page 2 / 7...
  • Page 3 (Ra) <0,8 μm. It is therefore well suited for use in hygienic processes or direct in con- centrated acids or alkalis. Media Secondary coil Primary coil Pt100 sensor www.baumer.com Data sheet AFI4 / AFI5 Page 3 / 7...
  • Page 4 ZPX4-740 DIN 11851 DN 65 ZPH1-5227 For pipe DN 40...50 ZPW2-526 Variline, type N ZPH1-524E SMS 1145 DN 38 ZPH1-5233 ZPX4-330 DN 60...150 ZPW2-527 SMS 1145 DN 51 ZPH1-5236 ZPX4-630 www.baumer.com Data sheet AFI4 / AFI5 Page 4 / 7...
  • Page 5 The sensors above is 3-A approved when mounted in one of the 3-A approved G1B mounting adapters, shown on page 4. 74-06 The short sensor is EHEDG approved when mounted in one of the 3-A approved G1B mounting adapters, shown on page 4. TYPE EL - CLASS I DECEMBER 2012 www.baumer.com Data sheet AFI4 / AFI5 Page 5 / 7...
  • Page 6 If a M12 4-pin connector for left and right side is selected the AFI4 is di- nected as common - for both Con. and Temp. 4...20 mA output. rectly compatible with the previous Baumer ISL conductivity transmitter. Right side electrical connection with relay output...
  • Page 7 37 mm version 3-A approved 60 and 83 mm version Calibration certificate Calibration certificate, conductivity (5 points) Calibration certificate, temperature (3 points) Calibration certificate, conductivity (5 points) and temperature (3 points) www.baumer.com Data sheet AFI4 / AFI5 Page 7 / 7...

This manual is also suitable for:

Combilyz afi4

Table of Contents